INTAKE AIR TEMPERATURE SENSOR INSPECTION

PROCEDURE


  1. INSPECT INTAKE AIR TEMPERATURE SENSOR


    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 2.21 to 2.65 kΩ
      B003LMKC04
      *a Component without harness connected (Intake Air Temperature Sensor) *b Resistance
      *c Temperature *d Acceptable Range

      If the result is not as specified, replace the intake air temperature sensor.

      Note

      When checking the intake air temperature sensor in water, keep the terminals dry. After the check, wipe the intake air temperature sensor dry.