PROCEDURE
INSPECT MANIFOLD ABSOLUTE PRESSURE SENSOR
Inspect the power source voltage.
Disconnect the manifold absolute pressure sensor connector.
| *a | Front view of wire harness connector (to Manifold Absolute Pressure Sensor) |
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
If the result is not as specified, inspect the wire harness or ECM Click here.
Connect the manifold absolute pressure sensor connector.
| *a | Component with harness connected (ECM) |
Check the power supply.
Turn the ignition switch to ON.
Disconnect the vacuum hose from the manifold absolute pressure sensor.
| *1 | Vacuum Pump |
|
Vacuum |
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
Tech Tips
The values in the "Condition" column are gauge pressures.
If the result is not as specified, replace the manifold absolute pressure sensor.
|
Pressure |
Using SST, measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Tech Tips
The values in the "Condition" column are gauge pressures.
If the result is not as specified, replace the manifold absolute pressure sensor.