LIGHTING (INT) SERVICE DATA

PERSONAL LIGHT
Connector Condition Tester Connection Condition Specified Condition
Component without harness connected

2 (B) - 1 (GND) (w/o Microphone)

5 (B) - 3 (GND) (w/ Microphone)

Map light switch LH OFF, RH OFF 10 kΩ or higher
Map light switch LH ON, RH OFF Below 1 Ω
Map light switch LH ON, RH ON Below 1 Ω
Map light switch LH OFF, RH ON Below 1 Ω

2 (B) - 3 (CTY) (w/o Microphone)

5 (B) - 1 (CTY) (w/ Microphone)

Courtesy switch OFF position 10 kΩ or higher
Courtesy switch DOOR position Below 1 Ω
A15 (MACC) - B5 (MACC) Always Below 1 Ω
A14 (MCO+) - B3 (MIC+) Below 1 Ω
A13 (MCO-) - B2 (MIC-) Below 1 Ω
FRONT DOOR COURTESY SWITCH
Connector Condition Tester Connection Switch Condition Specified Condition
Component without harness connected Terminal 1 - Switch body Pushed 5 MΩ or higher
Not pushed Below 20 Ω
REAR DOOR COURTESY SWITCH
Connector Condition Tester Connection Switch Condition Specified Condition
Component without harness connected Terminal 1 - Switch body Pushed 5 MΩ or higher
Not pushed Below 20 Ω
BACK DOOR COURTESY SWITCH (w/o Easy Closer)
Connector Condition Tester Connection Condition Specified Condition
Component without harness connected 2 (ACT-) - 3 (D+) Lock 10 kΩ or higher
Unlock Below 1 Ω
BACK DOOR COURTESY SWITCH (w/ Easy Closer)
Connector Condition Tester Connection Condition Specified Condition
Component without harness connected 3 (CLS) - 1 (E) Open position Below 1 Ω
Open position → Half-latch position Below 1 Ω → 10 kΩ or higher
Half-latch position 10 kΩ or higher
Full-latch position 10 kΩ or higher
Overstroke position 10 kΩ or higher
1 (E) - 4 (CTY) Open position Below 1 Ω
Half-latch position Below 1 Ω
Half-latch position → Full-latch position Below 1 Ω → 10 kΩ or higher
Full-latch position 10 kΩ or higher
Overstroke position 10 kΩ or higher
2 (FSW) - 1 (E) Open position 10 kΩ or higher
Open position → Half-latch position 10 kΩ or higher → Below 1 Ω → 10 kΩ or higher
Half-latch position 10 kΩ or higher
Half-latch position → Full-latch position 10 kΩ or higher → Below 1 Ω → 10 kΩ or higher
Full-latch position 10 kΩ or higher
Overstroke position 10 kΩ or higher
6 (OPN) - 1 (E) Sector gear in neutral position (Sector switch on) Below 1 Ω
Sector gear not in neutral position (Sector switch off) 10 kΩ or higher
RELAY
Connector Condition Tester Connection Switch Condition Specified Condition
Component without harness connected 3 - 5 Battery voltage not applied to terminals 1 and 2 10 kΩ or higher
Battery voltage applied to terminals 1 and 2 Below 1 Ω