| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | Cold | 835 to 1400 Ω |
| Hot | 1060 to 1645 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | Cold | 1630 to 2740 Ω |
| Hot | 2065 to 3225 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | Approx. 20°C (68°F) | 2.32 to 2.59 kΩ |
| Approx. 80°C (176°F) | 0.310 to 0.326 kΩ |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | Approx. 20°C (68°F) | 2.21 to 2.65 kΩ |
| Condition | Tester connection | Specified Condition |
|---|---|---|
| Ignition switch ON | 3(VC (+)) - 1(E(-)) | 4.75 to 5.25 V |
| Applied vacuum | - | - |
| 13.3 kPa (100 mmHg, 3.94 in.Hg) | C56-28 (PIM +) - C55-28 (E2 -) | 0.0 to 0.3 V |
| 26.6 kPa (199 mmHg, 7.85 in.Hg) | 0.2 to 0.6 V | |
| 40 kPa (300 mmHg, 11.81 in.Hg) | 0.4 to 0.8 V | |
| Applied pressure | - | - |
| 19.6 kPa (0.20 kgf/cm2, 2.84 psi) |
C56-28 (PIM +) - C55-28 (E2 -) | 0.05 to 0.3 V |
| 39.2 kPa (0.40 kgf/cm2, 5.68 in.Hg) |
0.25 to 0.55 V | |
| 58.8 kPa (0.60 kgf/cm2, 8.53 in.Hg) |
0.45 to 0.75 V | |
| 78.5 kPa (0.80 kgf/cm2, 11.4 in.Hg) |
0.65 to 0.95 V | |
| 98.0 kPa (1.00 kgf/cm2, 14.2 in.Hg) |
0.9 to 1.2 V |