ГЕНЕРАТОР СНЯТИЕ

PROCEDURE


  1. PRECAUTION

    Note

    After turning the ignition switch off, waiting time may be required before disconnecting the cable from the battery terminal. Therefore, make sure to read the disconnecting the cable from the battery terminal notice before proceeding with work.

    Click here

  2. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

    Note

    When disconnecting the cable, some systems need to be initialized after the cable is reconnected.

    Click here

  3. REMOVE FAN AND GENERATOR V BELT

    Click here

  4. REMOVE COMPRESSOR ASSEMBLY WITH MAGNETIC CLUTCH

    Click here

  5. REMOVE GENERATOR ASSEMBLY


    1. B0024PS

      Remove the terminal cap.

    2. Remove the nut and disconnect the wire harness from terminal B.

    3. Disconnect the generator connector.

    4. B00258N

      Disconnect the vacuum pump hose.

    5. Remove the union bolt to disconnect the vacuum pump oil inlet hose and remove the 2 gaskets.

    6. Detach the vacuum pump oil inlet hose from the cord clip.

    7. Disconnect the vacuum pump oil outlet hose.

    8. B0024RR

      Remove the 2 bolts and generator assembly.