CAUTION / NOTICE / HINT
The necessary procedures (adjustment, calibration, initialization, or registration) that must be performed after parts are removed, installed, or replaced during the air leaks from intake system removal/installation are shown below.
| Replacement Part or Procedure | Necessary Procedures | Effects/Inoperative when not Performed | Link |
|---|---|---|---|
| Air leaks from intake system | Inspection after repair | Poor idle, engine start, etc. |
CAUTION:
To prevent injury due to contact with an operating fan and generator V-belt or cooling fan, keep your hands and clothing away from the fan and generator V-belt and cooling fans when working in the engine compartment with the engine running.
PROCEDURE
INSPECT INTAKE SYSTEM
CAUTION:
To prevent injury due to contact with an operating fan and generator V-belt or cooling fan, keep your hands and clothing away from the fan and generator V-belt and cooling fans when working in the engine compartment with the engine running.
Tech Tips
Perform "Inspection After Repair" after repairing air leaks in the intake system.
Check that there is no air suction at the points shown in the illustration.