АДСОРБЕР ПРОВЕРКА

PROCEDURE


  1. INSPECT CANISTER


    1. Visually check the canister.


      1. Visually check the canister for cracks or damage.

        If cracks or damage are found, replace the canister.

    2. Inspect the ventilation of the canister.


      1. A01LAPSC01
        *a Port (A)
        *b Port (B)
        *c Port (C)
        *d Vacuum Pump

        Using a vacuum pump, apply vacuum (1.96 kPa (15 mmHg, 0.579 in. Hg)) to the port (A) with the port (B) and port (C) closed.

        OK
        Air does not flow.
      2. A01LDCTC01
        *a Port (A)
        *b Port (B)
        *c Port (C)
        *d Vacuum Pump

        Using a vacuum pump, apply vacuum (1.96 kPa (15 mmHg, 0.579 in. Hg)) to the port (A) with the port (C) closed.

        OK
        Air is sucked into the port (B).
      3. A01LC7RC01
        *a Port (A)
        *b Port (B)
        *c Port (C)
        *d Air

        Close the port (C) and apply compressed air (4.41 kPa (0.04 kgf/cm2, 0.6 psi)) to the port (A).

        OK
        Air flows out from the port (B).
      4. A01LF8MC01
        *a Port (A)
        *b Port (B)
        *c Port (C)
        *d Air

        Apply compressed air (4.41 kPa (0.04 kgf/cm2, 0.6 psi)) to the port (A).

        OK
        Air flows out from the port (B) and port (C).