КЛАПАН ПЕРЕКЛЮЧЕНИЯ ПОДАЧИ ВОЗДУХА (для моделей с вспомогательной системой подачи воздуха в нейтрализатор) ПРОВЕРКА

PROCEDURE


  1. INSPECT AIR SWITCHING VALVE ASSEMBLY


    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 4.5 to 5.5 Ω
      1 - Body ground Always 1 MΩ or higher
      2 - Body ground

      Tech Tips

      When measuring the resistance, make sure that the surface temperature of the air switching valve is 20°C (68°F).

      If the result is not as specified, replace the air switching valve assembly.

    2. A01L98AC03
      *a Air
      *b Port A
      *c Port B

      Check operation of the air switching valve.


      1. Check that air does not flow from port A to port B.

        If the result is not as specified, replace the air switching valve assembly.

      2. A01LEFAC05
        *a Air
        *b Port A
        *c Port B

        Apply battery voltage across terminals 1 and 2.

      3. Check that air flows from port A to port B.

        If the result is not as specified, replace the air switching valve assembly.