КЛАПАН ПРОДУВКИ АДСОРБЕРА ПРОВЕРКА

PROCEDURE


  1. INSPECT PURGE VSV


    1. Inspect the resistance.


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        1 - 2 20°C (68°F) 23 to 26 Ω
        1 - Body ground Always 10 MΩ or higher
        2 - Body ground

        If the result is not as specified, replace the purge VSV.

    2. Check the operation of the purge VSV.


      1. A01LCHKC01
        *a Port F
        *b Port E
        *c Does not flow
        *d Air

        Check that air does not flow from port F when air is applied to port E.

      2. A01LAQIC01
        *a Port F
        *b Port E
        *c Air

        Apply battery voltage to the connector and check the purge VSV operation.

        OK
        Measurement Condition Specified Condition

        Battery positive (+) → Terminal 1

        Battery negative (-) → Terminal 2

        Air flows from port E to port F

        If the result is not as specified, replace the purge VSV.