ПОДОГРЕВАЕМЫЙ КИСЛОРОДНЫЙ ДАТЧИК УСТАНОВКА

PROCEDURE


  1. INSTALL HEATED OXYGEN SENSOR


    1. A01W9LJC01
      *a Fulcrum Length

      Using SST, install the heated oxygen sensor.

      SST
      09224-00011
      Torque:
      Specified tightening torque
      44 N*m  { 449 kgf*cm, 32 ft.*lbf }

      Tech Tips


      • Calculate the torque wrench reading when changing the fulcrum length of the torque wrench.

        Click here

      • When using SST (fulcrum length of 30 mm (1.18 in.)) + torque wrench (fulcrum length of 255 mm (10.0 in.)): 39.4 N*m (402 kgf*cm, 29 ft.*lbf)

    2. for 2WD:

      Attach the sensor wire to the 4 clamps.

    3. for 4WD:

      Attach the sensor wire to the clamp.

    4. Connect the heated oxygen sensor connector.

  2. INSPECT FOR EXHAUST GAS LEAK

    Click here