CAUTION / NOTICE / HINT
Note
Inspect the fuses for circuits related to this system before performing the following procedure.
PROCEDURE
PERFORM ACTIVE TEST USING GTS (OPERATE VACUUM SWITCHING VALVE FOR ACIS)
| *1 | Air |
| *2 | Port F |
| *3 | Port E |
| *4 | Air Filter |
| *a | Vacuum Switching Valve Assembly is ON |
| *b | Vacuum Switching Valve Assembly is OFF |
Disconnect the vacuum hose from port F of the vacuum switching valve assembly (for acoustic control induction system).
Connect the GTS to the DLC3.
Start the engine.
Enter the following menus: Powertrain / Engine and ECT / Active Test / Active the VSV for Intake Control.
| Tester Display |
|---|
| Activate the VSV for Intake Control |
Operate the vacuum switching valve assembly for acoustic control induction system.
Check the vacuum switching valve assembly air flow when switching the vacuum switching valve assembly.
| OK | ||||||
|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| NG |
|
INSPECT VACUUM SWITCHING VALVE ASSEMBLY (FOR ACIS) Click here |
| OK |
|
CHECK VACUUM HOSES (VACUUM SWITCHING VALVE (FOR ACIS) - INTAKE AIR CONTROL VALVE, INTAKE AIR SURGE TANK)
Check the vacuum hoses.
| Result | |||
|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE VACUUM HOSES |
| OK |
|
INSPECT INTAKE AIR SURGE TANK (INTAKE AIR CONTROL VALVE)
Inspect the intake air control valve (for ACIS).
| Result | |||
|---|---|---|---|
|
| OK |
|
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE Click here |
| NG |
|
REPLACE INTAKE AIR SURGE TANK Click here |
INSPECT VACUUM SWITCHING VALVE ASSEMBLY (FOR ACIS)
Inspect the vacuum switching valve assembly (for ACIS).
| Result | |||
|---|---|---|---|
|
| NG |
|
REPLACE VACUUM SWITCHING VALVE ASSEMBLY (FOR ACIS) Click here |
| OK |
|
CHECK TERMINAL VOLTAGE (POWER SOURCE OF VACUUM SWITCHING VALVE ASSEMBLY (FOR ACIS))
| *a | Front view of wire harness connector (to Vacuum Switching Valve Assembly (for ACIS)) |
Disconnect the vacuum switching valve assembly (for ACIS) connector.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| NG |
|
CHECK HARNESS AND CONNECTOR (INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY - VACUUM SWITCHING VALVE ASSEMBLY (FOR ACIS)) Click here |
| OK |
|
CHECK HARNESS AND CONNECTOR (VACUUM SWITCHING VALVE ASSEMBLY (FOR ACIS) - ECM)
Disconnect the vacuum switching valve assembly (for ACIS) connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| OK |
|
REPLACE ECM Click here |
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
CHECK HARNESS AND CONNECTOR (INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY - VACUUM SWITCHING VALVE ASSEMBLY (FOR ACIS))
Disconnect the instrument panel junction block assembly connector.
Disconnect the vacuum switching valve assembly connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| OK |
|
GO TO ECM POWER SOURCE CIRCUIT Click here |
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |