AUTOMATIC HIGH BEAM MAIN SWITCH INSPECTION

PROCEDURE


  1. INSPECT AUTO HIGH BEAM SWITCH


    1. Inspect the automatic high beam main switch.


      1. A01IFMZC16
        *a

        Component without harness connected

        (Auto High Beam Switch)

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Switch Condition Specified Condition
        G55-4 - G55-1 Automatic high beam main switch off 10 kΩ or higher
        Automatic high beam main switch on Below 1 Ω

        If the result is not as specified, replace the combination switch assembly.

    2. Check the illumination.


      1. A01IFMZC17
        *a

        Component without harness connected

        (Auto High Beam Switch)

        Apply battery voltage to the connector and check the illumination conditions.

        OK
        Measurement Condition Specified Condition

        Battery positive (+) → G55-3 (ILL+)

        Battery negative (-) → G55-2 (ILL-)

        Illuminates

        If the result is not as specified, replace the combination switch assembly.