POWER SLIDE DOOR TOUCH SENSOR INSPECTION

PROCEDURE


  1. INSPECT POWER SLIDE DOOR SENSOR ASSEMBLY RH


    1. A01IFP6C04
      *a Free
      *b Pushed
      *c

      Component without harness connected

      (Power Slide Door Sensor Assembly RH)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      If the result is not as specified, replace the power slide door sensor assembly RH.

      Tester Connection Switch Condition Specified Condition
      2 (OS) - 3 (OSG) Free 0.95 to 1.05 kΩ
      2 (OS) - 3 (OSG) Pushed Below 100 Ω

      If the result is not as specified, replace the power slide door sensor assembly RH.

  2. INSPECT POWER SLIDE DOOR SENSOR ASSEMBLY LH


    1. A01IFP6C05
      *a Free
      *b Pushed
      *c

      Component without harness connected

      (Power Slide Door Sensor Assembly LH)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      1 (OS) - 2 (OSG) Free 0.95 to 1.05 kΩ
      1 (OS) - 2 (OSG) Pushed Below 100 Ω

      If the result is not as specified, replace the power slide door sensor assembly LH.