SLIDE DOOR CLOSER SYSTEM Slide Door Closer RH does not Operate

DESCRIPTION

The slide door closer controls the slide door motor unit RH (slide door ECU RH), receives signals from each switch inside the slide door lock assembly RH and drives the closer motor.

WIRING DIAGRAM

B006P00E06

CAUTION / NOTICE / HINT

Note

Inspect the fuses for circuits related to this system before performing the following procedure.

PROCEDURE


  1. CHECK SLIDE DOOR


    1. Check that no foreign objects are stuck between the vehicle body and the slide door.

      OK
      Door can be fully closed.
      Result
      Proceed to
      OK
      NG

    NG
    OK
  2. CHECK HARNESS AND CONNECTOR (SLIDE DOOR MOTOR UNIT RH - BATTERY AND BODY GROUND)


    1. B006POOC12
      *a

      Front view of wire harness connector

      (to Slide Door Motor Unit RH [Slide Door ECU RH])

      Disconnect the slide door motor unit RH (slide door ECU RH) connector.

    2. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      L15-1 (B) - Body ground Always 11 to 14 V
      L15-5 (ECUB) - Body ground Always 11 to 14 V
    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      L15-3 (GND) - Body ground Always Below 1 Ω
      Result
      Proceed to
      OK
      NG

    NG
    OK
  3. PERFORM ACTIVE TEST USING GTS


    1. Perform the Active Test according to the display on the GTS.

      Click here


      Body Electrical > Rear Right Door > Active Test
      Tester Display Measurement Item Control Range Diagnostic Note
      PSD Open Slide door open ON or OFF -

      Body Electrical > Rear Right Door > Active Test
      Tester Display
      PSD Open
      OK
      Slide door lock assembly (closer motor) operates.
      Result
      Proceed to
      OK
      NG

    NG
    OK
  4. READ VALUE USING GTS


    1. Read the Data List according to the display on the GTS.

      Click here


      Body Electrical > Rear Right Door > Data List
      Tester Display Measurement Item Normal Condition Reference Value Diagnostic Note
      Pawl Switch Status of the pawl switch ON or OFF

      ON: Pawl switch on

      OFF: Pawl switch off

      Check timing chart*
      Half Switch Status of the half-latch switch ON or OFF

      ON: Half-latch switch on

      OFF: Half-latch switch off

      Check timing chart*
      Full Switch Status of the full-latch switch ON or OFF

      ON: Full-latch switch on

      OFF: Full-latch switch off

      Check timing chart*
      Neutral Position Close Switch Status of the neutral position close switch ON or OFF

      ON: Neutral position close switch on

      OFF: Neutral position close switch off

      Check timing chart*


      Body Electrical > Rear Right Door > Data List
      Tester Display
      Pawl Switch
      Half Switch
      Full Switch
      Neutral Position Close Switch
      OK
      On the GTS screen, ON or OFF is displayed accordingly.
      Result
      Proceed to
      OK
      NG

    NG
    OK
  5. READ VALUE USING GTS


    1. Read the Data List according to the display on the GTS.

      Click here


      Body Electrical > Rear Right Door > Data List
      Tester Display Measurement Item Normal Condition Reference Value Diagnostic Note
      Handle Switch2 Status of inside handle (open switch) ON or OFF

      ON: Inside handle (open switch) operated

      OFF: Inside handle (open switch) not operated

      -
      Outside PSD Switch Status of outside handle (outside handle switch) ON or OFF

      ON: Outside handle operated (outside handle switch on)

      OFF: Outside handle not operated (outside handle switch off)

      -

      Body Electrical > Rear Right Door > Data List
      Tester Display
      Handle Switch2
      Outside PSD Switch
      OK
      On the GTS screen, ON or OFF is displayed accordingly.
      Result
      Proceed to
      OK
      NG

    OK
    NG
  6. INSPECT SLIDE DOOR LOCK ASSEMBLY RH


    1. Remove the slide door lock assembly RH.

      Click here

    2. Inspect the slide door lock assembly RH.

      Click here

      Result
      Proceed to
      OK
      NG

    NG
    OK
  7. CHECK HARNESS AND CONNECTOR (SLIDE DOOR LOCK ASSEMBLY RH - SLIDE DOOR MOTOR UNIT RH)


    1. Disconnect the J5 slide door lock assembly RH connector.

    2. Disconnect the J11 slide door motor unit RH (slide door ECU RH) connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      J5-1 (ACT+) - J11-1 (DC+) Always Below 1 Ω
      J5-4 (ACT-) - J11-2 (DC-) Always Below 1 Ω
      J5-1 (ACT+) or J11-1 (DC+) - Body ground Always 10 kΩ or higher
      J5-4 (ACT-) or J11-2 (DC-) - Body ground Always 10 kΩ or higher
      Result
      Proceed to
      OK
      NG

    OK
    NG
  8. INSPECT SLIDE DOOR LOCK ASSEMBLY RH


    1. Remove the slide door lock assembly RH.

      Click here

    2. Inspect the slide door lock assembly RH.

      Click here

      Result
      Proceed to
      OK
      NG

    NG
    OK
  9. CHECK HARNESS AND CONNECTOR (SLIDE DOOR LOCK ASSEMBLY RH - SLIDE DOOR MOTOR UNIT RH AND BODY GROUND)


    1. Disconnect the J5 slide door lock assembly RH connector.

    2. Disconnect the J11 and J12 slide door motor unit RH (slide door ECU RH) connectors.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      J5-6 (FUL) - J11-6 (FUL) Always Below 1 Ω
      J5-5 (HAF) - J12-2 (HAF) Always Below 1 Ω
      J5-10 (POL) - J12-4 (POL) Always Below 1 Ω
      J5-9 (NPC) - J12-6 (P) Always Below 1 Ω
      J5-7 (E1) - Body ground Always Below 1 Ω
      J5-6 (FUL) or J11-6 (FUL) - Body ground Always 10 kΩ or higher
      J5-5 (HAF) or J12-2 (HAF) - Body ground Always 10 kΩ or higher
      J5-10 (POL) or J12-4 (POL) - Body ground Always 10 kΩ or higher
      J5-9 (NPC) or J12-6 (P) - Body ground Always 10 kΩ or higher
      Result
      Proceed to
      OK
      NG

    OK
    NG
  10. INSPECT SLIDE DOOR HANDLE ASSEMBLY RH


    1. Remove the slide door handle assembly RH.

      Click here

    2. Inspect the slide door handle assembly RH.

      Click here

      Result
      Proceed to
      OK
      NG

    NG
    OK
  11. CHECK HARNESS AND CONNECTOR (SLIDE DOOR HANDLE ASSEMBLY RH - SLIDE DOOR MOTOR UNIT RH AND BODY GROUND)


    1. Disconnect the J8 slide door handle assembly RH connector.

    2. Disconnect the J11 and J12 slide door motor unit RH (slide door ECU RH) connectors.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      J8-2 (DS2) - J12-11 (DS2) Always Below 1 Ω
      J8-4 (E) - J11-9 (DSG) Always Below 1 Ω
      J8-3 (GND) - Body ground Always Below 1 Ω
      J8-2 (DS2) or J12-11 (DS2) - Body ground Always 10 kΩ or higher
      J8-4 (E) or J11-9 (DSG) - Body ground Always 10 kΩ or higher
      Result
      Proceed to
      OK
      NG

    OK
    NG