SLIDE DOOR MOTOR UNIT RH (SLIDE DOOR ECU RH)
Disconnect the J11, J12 and L15 slide door motor unit RH (slide door ECU RH) connectors.
Measure the voltage and resistance according to the value(s) in the table below.
| Tester Connection | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| L15-1 (B) - Body ground | R - Body ground | Power supply | Always | 11 to 14 V |
| L15-5 (ECUB) - Body ground | LG - Body ground | Power supply | Always | 11 to 14 V |
| L15-3 (GND) - Body ground | W-B - Body ground | Ground | Always | Below 1 Ω |
| J12-2 (HAF) - L15-3 (GND) | P - W-B | Half-latch switch input | Slide door RH open (half-latch switch on) → door ajar (half-latch switch off) Tech Tips For details regarding the on/off operation of the half-latch switch, refer to the timing chart in the system description. |
Below 1 Ω → 10 kΩ or higher |
| J11-6 (FUL) - L15-3 (GND) | BR - W-B | Full-latch switch input | Slide door RH open → fully closed (full-latch switch on) → fully closed (full-latch switch off) Tech Tips For details regarding the on/off operation of the full-latch switch, refer to the timing chart in the system description. |
Below 1 Ω → 10 kΩ or higher |
| J12-4 (POL) - L15-3 (GND) | G - W-B | Pawl switch input | Slide door RH open → fully closed Tech Tips For details regarding the on/off operation of the pawl switch, refer to the timing chart in the system description. |
10 kΩ or higher → (Below 1 Ω → 10 kΩ or higher) |
| J11-9 (DSG) - L15-3 (GND) | R - W-B | Outside handle switch signal | Outside handle not operated → outside handle operated | 10 kΩ or higher → Below 1 Ω |
| J12-11 (DS2) - L15-3 (GND) | LG - W-B | Inside handle open switch signal | Inside handle not operated → inside handle operated to open side | 10 kΩ or higher → Below 1 Ω |
Reconnect the J11, J12 and L15 slide door motor unit RH (slide door ECU RH) connectors.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| J11-1 (DC+) - L15-3 (GND) | L - W-B | Slide door closer output (close rotation) | Slide door RH open → ajar → motor normal rotation operation → reverse operation → operation complete (fully closed condition) | Below 1 V → Below 1 V → 11 to 14 V → Below 1 V → Below 1 V |
| J11-2 (DC-) - L15-3 (GND) | G - W-B | Slide door closer output (release rotation) | Slide door RH open → ajar → motor normal rotation operation → reverse operation → operation complete (fully closed condition) | Below 1 V → Below 1 V → Below 1 V → 11 to 14 V → Below 1 V |
| J12-6 (P) - L15-3 (GND) | B - W-B | Neutral position close switch input | Slide door RH open → ajar → motor normal rotation operation in progress → reverse operation → operation complete (fully closed condition) Tech Tips For details regarding the on/off operation of the neutral position switch, refer to the timing chart in the system description. |
11 to 14 V → 11 to 14 V → Below 1 V → Below 1 V → 11 to 14 V |
SLIDE DOOR MOTOR UNIT LH (SLIDE DOOR ECU LH)
Disconnect the J24, J25 and K19 slide door motor unit LH (slide door ECU LH) connectors.
Measure the voltage and resistance according to the value(s) in the table below.
| Tester Connection | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| K19-1 (B) - Body ground | L - Body ground | Power supply | Always | 11 to 14 V |
| K19-5 (ECUB) - Body ground | G - Body ground | Power supply | Always | 11 to 14 V |
| K19-3 (GND) - Body ground | W-B - Body ground | Ground | Always | Below 1 Ω |
| J25-2 (HAF) - K19-3 (GND) | P - W-B | Half-latch switch input | Slide door LH open (half-latch switch on) → door ajar (half-latch switch off) Tech Tips For details regarding the on/off operation of the half-latch switch, refer to the timing chart in the system description. |
Below 1 Ω → 10 kΩ or higher |
| J24-6 (FUL) - K19-3 (GND) | BR - W-B | Full-latch switch input | Slide door LH open → fully closed (full-latch switch on) → fully closed (full-latch switch) Tech Tips For details regarding the on/off operation of the full-latch switch, refer to the timing chart in the system description. |
Below 1 Ω → 10 kΩ or higher |
| J25-4 (POL) - K19-3 (GND) | G - W-B | Pawl switch input | Slide door LH open → fully closed Tech Tips For details regarding the on/off operation of the pawl switch, refer to the timing chart in the system description. |
10 kΩ or higher → (Below 1 Ω → 10 kΩ or higher) |
| J24-9 (DSG) - K19-3 (GND) | R - W-B | Outside handle switch signal | Outside handle not operated → outside handle operated | 10 kΩ or higher → Below 1 Ω |
| J25-11 (DS2) - K19-3 (GND) | LG - W-B | Inside handle open switch signal | Inside handle not operated → inside handle operated to open side | 10 kΩ or higher → Below 1 Ω |
Reconnect the J24, J25 and K19 slide door motor unit LH (slide door ECU LH) connectors.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| J24-1 (DC+) - K19-3 (GND) | L - W-B | Slide door closer output (close rotation) | Slide door LH open → ajar → motor normal rotation operation → reverse operation → operation complete (fully closed condition) | Below 1 V → Below 1 V → 11 to 14 V → Below 1 V → Below 1 V |
| J24-2 (DC-) - K19-3 (GND) | G - W-B | Slide door closer output (release rotation) | Slide door LH open → ajar → motor normal rotation operation → reverse operation → operation complete (fully closed condition) | Below 1 V → Below 1 V → Below 1 V → 11 to 14 V → Below 1 V |
| J25-6 (NPC) - K19-3 (GND) | B - W-B | Neutral position close switch input | Slide door LH open → ajar → motor normal rotation operation in progress → reverse operation → operation complete (fully closed condition) Tech Tips For details regarding the on/off operation of the neutral position switch, refer to the timing chart in the system description. |
11 to 14 V → Below 1 V → Below 1 V → Below 1 V → 11 to 14 V |