POWER SLIDE DOOR SYSTEM DATA LIST / ACTIVE TEST


  1. DATA LIST

    Tech Tips

    Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.

    Note

    In the following table, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.


    1. Connect the GTS to the DLC3.

    2. Turn the engine switch on (IG).

    3. Turn the GTS on.

    4. Enter the following menus: Body Electrical / Rear Left Door, Rear Right Door or Main Body / Data List.

    5. Read the Data List according to the display on the GTS.


      Body Electrical > Rear Left Door > Data List
      Tester Display Measurement Item Normal Condition Reference Value Diagnostic Note
      Pawl Switch Status of the pawl switch ON or OFF

      ON: Pawl switch on

      OFF: Pawl switch off

      Check timing chart*
      Half Switch Status of the half-latch switch ON or OFF

      ON: Half-latch switch on

      OFF: Half-latch switch off

      Check timing chart*
      Full Switch Status of the full-latch switch ON or OFF

      ON: Full-latch switch on

      OFF: Full-latch switch off

      Check timing chart*
      Neutral Position Close Switch Status of the neutral position close switch ON or OFF

      ON: Neutral position close switch on

      OFF: Neutral position close switch off

      Check timing chart*
      Neutral Position Release Switch Status of the neutral position release switch ON or OFF

      ON: Neutral position release switch on

      OFF: Neutral position release switch off

      Check timing chart*
      PSD Touch Sensor Power slide door sensor assembly LH signal OFF, ON or Open

      OFF: Power slide door sensor assembly LH not pressed

      ON: Power slide door sensor assembly LH pressed

      Open: Power slide door sensor assembly LH open

      -
      Handle Switch1 Inside handle switch (close switch) signal ON or OFF

      ON: Slide door inside handle close operation performed (inside handle switch [close switch] on)

      OFF: Slide door inside handle operation not performed or open operation performed (inside handle switch [close switch] off)

      -
      Handle Switch2 Inside handle switch (open switch) signal ON or OFF

      ON: Slide door inside handle open operation performed (inside handle switch [open switch] on)

      OFF: Slide door inside handle operation not performed or close operation performed (inside handle switch [open switch] off)

      -
      PSD Main Switch Power slide door main switch or slide door half open stopper control assembly signal ON or OFF

      ON: Power slide door main switch and slide door half open stopper control assembly on

      OFF: Power slide door main switch or slide door half open stopper control assembly off

      -
      Door Sensor1 Power slide door motor pulse sensor signal ON or OFF ON and OFF displayed alternately -
      Door Sensor2 Power slide door motor pulse sensor signal ON or OFF ON and OFF displayed alternately -
      Power Voltage Battery voltage Min. 0, Max. 25.5 [V] 11 to 14 [V] -
      Door Position Slide door position Min. 0, Max. 65535 [Pulse] Current slide door position displayed -
      One Touch Open/Close Switch One-touch switch signal ON or OFF

      ON: One-touch switch on

      OFF: One-touch switch off

      -
      Status of PSD Sliding Motor Power slide door motor condition Stop, Opening or Closing Power slide door motor condition displayed -
      Status of PSD Clutch Power slide door clutch condition ON or OFF Power slide door clutch condition displayed -
      Status of PSD Buzzer Power slide door buzzer condition ON or OFF Buzzer status displayed -
      Status of PSD Latch Operation Latch switch condition Stop, Release or Close Latch switch condition displayed -
      Outside PSD Switch Status of outside handle (outside handle switch) ON or OFF

      ON: Outside handle operated (outside handle switch on)

      OFF: Outside handle not operated (outside handle switch off)

      -
      PSD SW Operation Slide door switch setting condition 0.0 s or 0.8 s Customization status displayed -
      PSD Buzz In Use Power slide door warning buzzer setting condition ON or OFF Customization status displayed -
      Wireless PSD SW Operation Wireless operation setting condition OFF, 1Oper, 2Oper, long, 2/OM or L/OM Customization status displayed -
      One Touch Open/Close SW Operation Setting (RL) One-touch switch setting condition Short Push (0.3s), Middle Push (0.5s), Long Push (0.8s) or OFF Customization status displayed -
      #Codes Number of trouble codes Min. 0, Max. 255 Number of DTCs will be displayed -


      Body Electrical > Rear Right Door > Data List
      Tester Display Measurement Item Normal Condition Reference Value Diagnostic Note
      Pawl Switch Status of the pawl switch ON or OFF

      ON: Pawl switch on

      OFF: Pawl switch off

      Check timing chart*
      Half Switch Status of the half-latch switch ON or OFF

      ON: Half-latch switch on

      OFF: Half-latch switch off

      Check timing chart*
      Full Switch Status of the full-latch switch ON or OFF

      ON: Full-latch switch on

      OFF: Full-latch switch off

      Check timing chart*
      Neutral Position Close Switch Status of the neutral position close switch ON or OFF

      ON: Neutral position close switch on

      OFF: Neutral position close switch off

      Check timing chart*
      Neutral Position Release Switch Status of the neutral position release switch ON or OFF

      ON: Neutral position release switch on

      OFF: Neutral position release switch off

      Check timing chart*
      PSD Touch Sensor Power slide door sensor assembly RH signal OFF, ON or Open

      OFF: Power slide door sensor assembly RH not pressed

      ON: Power slide door sensor assembly RH pressed

      Open: Power slide door sensor assembly RH open

      -
      Handle Switch1 Inside handle switch (close switch) signal ON or OFF

      ON: Slide door inside handle close operation performed (inside handle switch [close switch] on)

      OFF: Slide door inside handle operation not performed or open operation performed (inside handle switch [close switch] off)

      -
      Handle Switch2 Inside handle switch (open switch) signal ON or OFF

      ON: Slide door inside handle open operation performed (inside handle switch [open switch] on)

      OFF: Slide door inside handle operation not performed or close operation performed (inside handle switch [open switch] off)

      -
      PSD Main Switch Power slide door main switch signal ON or OFF

      ON: Power slide door main switch on

      OFF: Power slide door main switch off

      -
      Door Sensor1 Power slide door motor pulse sensor signal ON or OFF ON and OFF displayed alternately -
      Door Sensor2 Power slide door motor pulse sensor signal ON or OFF ON and OFF displayed alternately -
      Power Voltage Battery voltage Min. 0, Max. 25.5 [V] 11 to 14 [V] -
      Door Position Slide door position Min. 0, Max. 65535 [Pulse] Current slide door position displayed -
      One Touch Open/Close Switch One-touch switch signal ON or OFF

      ON: One-touch switch on

      OFF: One-touch switch off

      -
      Status of PSD Sliding Motor Power slide door motor condition Stop, Opening or Closing Power slide door motor condition displayed -
      Status of PSD Clutch Power slide door clutch condition ON or OFF Power slide door clutch condition displayed -
      Status of PSD Buzzer Power slide door buzzer condition ON or OFF Buzzer status displayed -
      Status of PSD Latch Operation Latch switch condition Stop, Release or Close Latch switch condition displayed -
      Outside PSD Switch Status of outside handle (outside handle switch) ON or OFF

      ON: Outside handle operated (outside handle switch on)

      OFF: Outside handle not operated (outside handle switch off)

      -
      PSD SW Operation Slide door switch setting condition 0.0 s or 0.8 s Customization status displayed -
      PSD Buzz In Use Power slide door warning buzzer setting condition ON or OFF Customization status displayed -
      Wireless PSD SW Operation Wireless operation setting condition OFF, 1Oper, 2Oper, long, 2/OM or L/OM Customization status displayed -
      One Touch Open/Close SW Operation Setting (RR) One-touch switch setting condition Short Push (0.3s), Middle Push (0.5s), Long Push (0.8s) or OFF Customization status displayed -
      #Codes Number of trouble codes Min. 0, Max. 255 Number of DTCs will be displayed -


      Body Electrical > Main Body > Data List
      Tester Display Measurement Item Normal Condition Reference Value Diagnostic Note
      Slide Door RH Close Switch Slide door close switch RH signal ON or OFF

      ON: Slide door close switch RH on

      OFF: Slide door close switch RH off

      -
      Slide Door LH Close Switch Slide door close switch LH signal ON or OFF

      ON: Slide door close switch LH on

      OFF: Slide door close switch LH off

      -
      Slide Door RH Open Switch Slide door open switch RH signal ON or OFF

      ON: Slide door open switch RH on

      OFF: Slide door open switch RH off

      -
      Slide Door LH Open Switch Slide door open switch LH signal ON or OFF

      ON: Slide door open switch LH on

      OFF: Slide door open switch LH off

      -
  2. Tech Tips

    Using the GTS to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.

    ACTIVE TEST


    1. Connect the GTS to the DLC3.

    2. Turn the engine switch on (IG).

    3. Turn the GTS on.

    4. Enter the following menus: Body Electrical / Rear Left Door or Rear Right Door / Active Test.

    5. Perform the Active Test according to the display on the GTS.


      Body Electrical > Rear Left Door > Active Test
      Tester Display Measurement Item Control Range Diagnostic Note
      PSD Motor Power slide door motor OFF, Forward or Reverse Power slide door control clutch is off while power slide door motor is operating
      PSD Clutch Power slide door control clutch ON or OFF Power slide door motor is off when clutch is on
      PSD Buzzer Power slide door warning buzzer ON or OFF -
      PSD Open Power slide door open ON or OFF -

      Body Electrical > Rear Right Door > Active Test
      Tester Display Measurement Item Control Range Diagnostic Note
      PSD Motor Power slide door motor OFF, Forward or Reverse Power slide door control clutch is off while power slide door motor is operating
      PSD Clutch Power slide door control clutch ON or OFF Power slide door motor is off when clutch is on
      PSD Buzzer Power slide door warning buzzer ON or OFF -
      PSD Open Power slide door open ON or OFF -