POWER SLIDE DOOR SYSTEM, Diagnostic DTC:B225E

DTC Code DTC Name
B225E Power Slide Door Neutral Closer Switch RH Malfunction during Close Operation

DESCRIPTION

This DTC is output when the neutral position switch (close/release) in the slide door lock assembly RH inputs a malfunction signal.

DTC No. Detection Item DTC Detection Condition Trouble Area
B225E Power Slide Door Neutral Closer Switch RH Malfunction during Close Operation Slide door motor unit RH (slide door ECU RH) detects neutral position switch (close/release) malfunction signal in slide door lock assembly RH 5 times consecutively
  • Slide door lock assembly RH

  • Slide door motor unit RH (slide door ECU RH)

  • Harness or connector

WIRING DIAGRAM

B006PPXE07

PROCEDURE


  1. CHECK FOR DTC


    1. Clear the DTC.

      Click here


      Body Electrical > Rear Right Door > Clear DTCs
    2. Check for DTC.

      Click here


      Body Electrical > Rear Right Door > Trouble Codes
      OK
      DTC B225E is not output
      Result
      Proceed to
      OK
      NG

    OK
    NG
  2. READ VALUE USING GTS


    1. Read the Data List according to the display on the GTS.

      Click here


      Body Electrical > Rear Right Door > Data List
      Tester Display Measurement Item Normal Condition Reference Value Diagnostic Note
      Neutral Position Close Switch Status of the neutral position close switch ON or OFF

      ON: Neutral position close switch on

      OFF: Neutral position close switch off

      Check timing chart*
      Neutral Position Release Switch Status of the neutral position release switch ON or OFF

      ON: Neutral position release switch on

      OFF: Neutral position release switch off

      Check timing chart*


      Body Electrical > Rear Right Door > Data List
      Tester Display
      Neutral Position Close Switch
      Neutral Position Release Switch
      OK
      On the GTS screen, ON or OFF is displayed accordingly.
      Result
      Proceed to
      OK
      NG

    OK
    NG
  3. INSPECT SLIDE DOOR LOCK ASSEMBLY RH


    1. Remove the slide door lock assembly RH.

      Click here

    2. Inspect the slide door lock assembly RH.

      Click here

      Result
      Proceed to
      OK
      NG

    NG
    OK
  4. CHECK HARNESS AND CONNECTOR (SLIDE DOOR LOCK ASSEMBLY RH - SLIDE DOOR MOTOR UNIT RH AND BODY GROUND)


    1. Disconnect the J5 slide door lock assembly RH connector.

    2. Disconnect the J12 slide door motor unit RH (slide door ECU RH) connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      J5-9 (NPC) - J12-6 (P) Always Below 1 Ω
      J5-8 (NPR) - J12-9 (SPD) Always Below 1 Ω
      J5-7 (E1) - Body ground Always Below 1 Ω
      J5-9 (NPC) or J12-6 (P) - Body ground Always 10 kΩ or higher
      J5-8 (NPR) or J12-9 (SPD) - Body ground Always 10 kΩ or higher
      Result
      Proceed to
      OK
      NG

    OK
    NG