POWER WINDOW MASTER SWITCH INSPECTION

PROCEDURE


  1. INSPECT MULTIPLEX NETWORK MASTER SWITCH ASSEMBLY (for LHD)


    1. A01IJJIC01
      *a LED
      *b

      Component without harness connected

      (Multiplex Network Master Switch Assembly)

      Check that the LED illuminates.


      1. Apply battery voltage to the multiplex network master switch assembly and check that the LED illuminates.

        OK
        Measurement Condition Specified Condition

        Battery positive (+) → 3 (ILL+)

        Battery negative (-) → 13 (ILL-)

        LED illuminates

        If the result is not as specified, replace the multiplex network master switch assembly.

  2. INSPECT MULTIPLEX NETWORK MASTER SWITCH ASSEMBLY (for RHD)


    1. A01IFH7C03
      *a LED
      *b

      Component without harness connected

      (Multiplex Network Master Switch Assembly)

      Check that the LED illuminates.


      1. Apply battery voltage to the multiplex network master switch assembly and check that the LED illuminates.

        OK
        Measurement Condition Specified Condition

        Battery positive (+) → 3 (ILL+)

        Battery negative (-) → 13 (ILL-)

        LED illuminates

        If the result is not as specified, replace the multiplex network master switch assembly.