AIR CONDITIONING PRESSURE SENSOR INSTALLATION

PROCEDURE


  1. INSTALL AIR CONDITIONER PRESSURE SENSOR


    1. Remove the vinyl tape from the air conditioner tube and accessory assembly and the connecting part of the air conditioner pressure sensor.

    2. Apply sufficient compressor oil to the O-ring of a new air conditioner pressure sensor and the connecting surface.

      Compressor Oil
      ND-OIL 8 or equivalent

      Note

      Keep the O-rings and O-ring fitting surfaces free of foreign matter.

    3. A01IIXOC02
      *A for 2AR-FE
      *B for 2GR-FE
      *a Turn
      *b Hold

      Using a 27 mm deep socket wrench, install the air conditioner pressure sensor.

      Torque:
      10.8 N*m  { 110 kgf*cm, 8 ft.*lbf }
    4. A01IGACC02
      *A for 2AR-FE
      *B for 2GR-FE

      Connect the connector.

  2. INSTALL WASHER INLET SUB-ASSEMBLY

    Click here

  3. CHARGE AIR CONDITIONING SYSTEM WITH REFRIGERANT

    Click here

  4. WARM UP WARM UP ENGINE

    Click here

  5. INSPECT FOR REFRIGERANT LEAK

    Click here