FRONT EVAPORATOR TEMPERATURE SENSOR(for LHD) INSTALLATION

PROCEDURE


  1. INSTALL NO. 1 COOLER THERMISTOR (FRONT EVAPORATOR TEMPERATURE SENSOR)


    1. B006KXDN01

      Install the No. 1 cooler thermistor (front evaporator temperature sensor) as shown in the illustration.

      Installation Position
      Position Measurement
      A 45 to 55 mm (1.77 to 2.17 in.)
      B 23 to 27 mm (0.91 to 1.06 in.)
      C 54.4 mm (2.14 in.)(8 Fins)
      D 61.1 mm (2.41 in.) (9 Fins)

      Note


      • Be sure to insert the No. 1 cooler thermistor (front evaporator temperature sensor) only once because reinserting it into the same position will not allow it to be firmly secured.

      • When reusing the evaporator, insert the No. 1 cooler thermistor (front evaporator temperature sensor) one row next to the one that has been used previously.

      • After inserting the thermistor, do not apply excessive force to the wire.

  2. INSTALL NO. 1 COOLER EVAPORATOR SUB-ASSEMBLY

    Click here

  3. INSTALL COOLER EXPANSION VALVE

    Click here

  4. INSTALL HEATER RADIATOR UNIT SUB-ASSEMBLY

    Click here

  5. INSTALL AIR CONDITIONING HARNESS ASSEMBLY

    Click here

  6. INSTALL BLOWER ASSEMBLY

    Click here

  7. INSTALL AIR CONDITIONER UNIT ASSEMBLY

    Click here