METER / GAUGE SYSTEM Operating Light Control Rheostat does not Change Light Brightness

DESCRIPTION

The combination meter assembly receives signals from this circuit to adjust the illumination of the combination meter assembly. The combination meter assembly sets the illumination level based on the user operation of the light control rheostat switch in the trip switch.

WIRING DIAGRAM

B006OXHE02

CAUTION / NOTICE / HINT

Note

When replacing the combination meter assembly, make sure to replace it with a new one.

Tech Tips


  • The meter illumination level can be adjusted by pressing the light control rheostat switch.

  • The meter illumination dims when the taillights are turned on.

  • Setting the meter illumination to maximum brightness cancels the above dimming of the meter illumination.

PROCEDURE


  1. READ VALUE USING GTS (LIGHT CONTROL UP SWITCH, LIGHT CONTROL DOWN SWITCH)


    1. Using the GTS, read the Data List.

      Click here


      Body Electrical > Combination Meter > Data List
      Tester Display Measurement Item Range Normal Condition Diagnostic Note
      Light Control Up Switch Light control rheostat up switch OFF or ON

      OFF: Light control rheostat up switch released

      ON: Light control rheostat up switch pressed

      -
      Light Control Down Switch Light control rheostat down switch OFF or ON

      OFF: Light control rheostat down switch released

      ON: Light control rheostat down switch pressed

      -

      Body Electrical > Combination Meter > Data List
      Tester Display
      Light Control Up Switch
      Light Control Down Switch
      OK
      Light control rheostat up or down switch condition displayed on the GTS changes with the actual switch operation.
      Result
      Proceed to
      OK
      NG

    OK
    NG
  2. INSPECT TRIP SWITCH


    1. Remove the trip switch.

      Click here

    2. Inspect the trip switch.

      Click here

      Result
      Proceed to
      OK
      NG

    NG
    OK
  3. CHECK HARNESS AND CONNECTOR (TRIP SWITCH - COMBINATION METER ASSEMBLY AND BODY GROUND)


    1. Disconnect the G16 combination meter assembly connector.

    2. Disconnect the G54 trip switch connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      G16-19(TR) - G54-3(UP) Always Below 1 Ω
      G16-20(TC) - G54-7(DOWN) Always Below 1 Ω
      G54-5(E) - Body ground Always Below 1 Ω
      G16-19(TR) or G54-3(UP) - Body ground Always 10 kΩ or higher
      G16-20(TC) or G54-7(DOWN) - Body ground Always 10 kΩ or higher
      Result
      Proceed to
      OK
      NG

    OK
    NG