CEILING LIGHT SWITCH INSPECTION

PROCEDURE


  1. INSPECT INTEGRATION CONTROL AND PANEL ASSEMBLY (CEILING LIGHT SWITCH)


    1. A01IKK5C01
      *a

      Component without harness connected

      (Integration Control and Panel Assembly (Ceiling Light Switch))

      *b Light Switch
      *c Light Color Change Switch

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      8 (LP+) - 12 (GND) Light switch is pressed Below 1 Ω
      Light switch is not pressed 1 kΩ or higher
      9 (M1) - 12 (GND) Upper part of light color change switch is pressed Below 1 Ω
      Upper part of light color change switch is not pressed 1 kΩ or higher
      10 (M2) - 12 (GND) Lower part of light color change switch is pressed Below 1 Ω
      Lower part of light color change switch is not pressed 1 kΩ or higher

      If the result is not as specified, replace the integration control and panel assembly (ceiling light switch).