SLIDE DOOR LOCK INSPECTION

PROCEDURE


  1. INSPECT SLIDE DOOR HANDLE ASSEMBLY LH


    1. A01II7MC03
      *a

      Component without harness connected

      (Slide Door Handle Assembly LH)

      *b Lock
      *c Unlock

      Check the operation.


      1. Apply battery voltage and check the operation of the door lock actuator.

        OK
        Battery Connection Result

        Battery positive (+) - 2 (L)

        Battery negative (-) - 3 (UL)

        Locked

        Battery positive (+) - 3 (UL)

        Battery negative (-) - 2 (L)

        Unlocked

        If the result is not as specified, replace the slide door handle assembly LH.

    2. Check the resistance of the position switch.


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        1 (LSSR) - 4 (E) Locked 10 kΩ or higher
        1 (LSSR) - 4 (E) Unlocked Below 1 Ω

        If the result is not as specified, replace the slide door handle assembly LH.

    3. A01IGFQC02
      *a

      Component without harness connected

      (Slide Door Handle Assembly LH)

      *b Close Side
      *c Open Side

      Check the resistance of the handle switch. (Inside Handle Switch)


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        2 (GND) - 4 (DS1) Neutral position 10 kΩ or higher
        2 (GND) - 4 (DS1) Handle pulled (open side) 10 kΩ or higher
        2 (GND) - 4 (DS1) Handle pulled (close side) Below 1 Ω
        2 (GND) - 3 (DS2) Neutral position 10 kΩ or higher
        2 (GND) - 3 (DS2) Handle pulled (open side) Below 1 Ω
        2 (GND) - 3 (DS2) Handle pulled (close side) 10 kΩ or higher

        If the result is not as specified, replace the slide door handle assembly LH.

    4. A01IF8WC02
      *a

      Component without harness connected

      (Slide Door Handle Assembly LH)

      *b Neutral Position
      *c Operate Lever

      Check the resistance of the handle switch. (Outside Handle Switch)


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        1 (E) - 2 (GND) Neutral position 10 kΩ or higher
        1 (E) - 2 (GND) When lever is operated Below 1 Ω

        If the result is not as specified, replace the slide door handle assembly LH.

  2. INSPECT SLIDE DOOR HANDLE ASSEMBLY RH


    1. A01IIERC02
      *a

      Component without harness connected

      (Slide Door Handle Assembly RH)

      *b Lock
      *c Unlock

      Check the operation.


      1. Apply battery voltage and check the operation of the door lock actuator.

        OK
        Battery Connection Result

        Battery positive (+) - 2 (L)

        Battery negative (-) - 3 (UL)

        Locked

        Battery positive (+) - 3 (UL)

        Battery negative (-) - 2 (L)

        Unlocked

        If the result is not as specified, replace the slide door handle assembly RH.

    2. Check the resistance of the position switch.


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        1 (LSSR) - 4 (E) Lock 10 kΩ or higher
        1 (LSSR) - 4 (E) Unlock Below 1 Ω

        If the result is not as specified, replace the slide door handle assembly RH.

    3. A01II9JC03
      *a

      Component without harness connected

      (Slide Door Handle Assembly RH)

      *b Close Side
      *c Open Side

      Check the resistance of the handle switch. (Inside Handle Switch)


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        1 (DS1) - 3 (GND) Neutral position 10 kΩ or higher
        1 (DS1) - 3 (GND) Handle pulled (open side) 10 kΩ or higher
        1 (DS1) - 3 (GND) Handle pulled (close side) Below 1 Ω
        2 (DS2) - 3 (GND) Neutral position 10 kΩ or higher
        2 (DS2) - 3 (GND) Handle pulled (open side) Below 1 Ω
        2 (DS2) - 3 (GND) Handle pulled (close side) 10 kΩ or higher

        If the result is not as specified, replace the slide door handle assembly RH.

    4. A01IG6MC03
      *a

      Component without harness connected

      (Slide Door Handle Assembly RH)

      *b Neutral Position
      *c Operate Lever

      Check the resistance of the handle switch. (Outside Handle Switch)


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        3 (GND) - 4 (E) Neutral position 10 kΩ or higher
        3 (GND) - 4 (E) When lever is operated Below 1 Ω

        If the result is not as specified, replace the slide door handle assembly RH.

  3. INSPECT SLIDE DOOR LOCK ASSEMBLY LH


    1. A01IJ01C02
      *a

      Component without harness connected

      (Slide Door Lock Assembly LH)

      *b Direction of Release Operation
      *c Direction of Close Operation

      Check the operation.


      1. Apply battery voltage and check the operation of the door lock motor.

        OK
        Battery Connection Result

        Battery positive (+) - 1 (ACT+)

        Battery negative (-) - 4 (ACT-)

        Close Operation

        Battery positive (+) - 4 (ACT-)

        Battery negative (-) - 1 (ACT+)

        Release Operation

        If the result is not as specified, replace the slide door lock assembly LH.

    2. A01II6AC02
      *1 Active Lever
      *a

      Component without harness connected

      (Slide Door Lock Assembly LH)

      *b Direction of Release Operation
      *c Direction of Close Operation
      *d Neutral Release Switch ON Area
      *e Neutral Close Switch ON Area
      *f Neutral Position (Neutral Release Switch)
      *g Neutral Position (Neutral Close Switch)
      *h Neutral Area

      Check the resistance of the neutral switch.


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Neutral Close Switch
        Tester Connection Condition Specified Condition
        7 (E1) - 9 (NPC)

        Neutral position

        (neutral release switch)

        10 kΩ or higher
        7 (E1) - 9 (NPC)

        Neutral position

        (neutral close switch)

        10 kΩ or higher
        7 (E1) - 9 (NPC) Active lever is moved in direction of release operation 10 kΩ or higher
        7 (E1) - 9 (NPC) Active lever is moved in direction of close operation Below 1 Ω
        Standard Resistance
        Neutral Release Switch
        Tester Connection Condition Specified Condition
        7 (E1) - 8 (NPR)

        Neutral position

        (neutral release switch)

        10 kΩ or higher
        7 (E1) - 8 (NPR)

        Neutral position

        (neutral close switch)

        10 kΩ or higher
        7 (E1) - 8 (NPR) Active lever is moved in direction of release operation Below 1 Ω
        7 (E1) - 8 (NPR) Active lever is moved in direction of close operation 10 kΩ or higher

        If the result is not as specified, replace the slide door lock assembly LH.

    3. A01IETFC02
      *a

      Component without harness connected

      (Slide Door Lock Assembly LH)

      *b Latch Open Position
      *c Half-latch Position
      *d Full-latch Position
      *e Over-latch Position

      Check the resistance of the latch switch and pole switch.


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Full Latch Switch
        Tester Connection Condition Specified Condition
        6 (FUL) - 7 (E1) Latch Open Below 1 Ω
        6 (FUL) - 7 (E1) Half-latch Below 1 Ω
        6 (FUL) - 7 (E1) Full-latch 10 kΩ or higher
        6 (FUL) - 7 (E1) Over-latch 10 kΩ or higher
        Standard Resistance
        Half Latch Switch
        Tester Connection Condition Specified Condition
        5 (HAF) - 7 (E1) Latch Open Below 1 Ω
        5 (HAF) - 7 (E1) Half-latch 10 kΩ or higher
        5 (HAF) - 7 (E1) Full-latch 10 kΩ or higher
        5 (HAF) - 7 (E1) Over-latch 10 kΩ or higher
        Standard Resistance
        Pole Switch
        Tester Connection Condition Specified Condition
        7 (E1) - 10 (POL) Open Below 1 Ω
        7 (E1) - 10 (POL) Between open and half-latch 10 kΩ or higher → Below 1 Ω
        7 (E1) - 10 (POL) Half-latch 10 kΩ or higher
        7 (E1) - 10 (POL) Between half-latch and full-latch 10 kΩ or higher → Below 1 Ω
        7 (E1) - 10 (POL) Full-latch 10 kΩ or higher
        7 (E1) - 10 (POL) Over-latch 10 kΩ or higher

        If the result is not as specified, replace the slide door lock assembly LH.

  4. INSPECT SLIDE DOOR LOCK ASSEMBLY RH


    1. A01IFGZC02
      *a

      Component without harness connected

      (Slide Door Lock Assembly RH)

      *b Direction of Release Operation
      *c Direction of Close Operation

      Check the operation.


      1. Apply battery voltage and check the operation of the door lock motor.

        OK
        Battery Connection Result

        Battery positive (+) - 1 (ACT+)

        Battery negative (-) - 4 (ACT-)

        Close Operation

        Battery positive (+) - 4 (ACT-)

        Battery negative (-) - 1 (ACT+)

        Release Operation

        If the result is not as specified, replace the slide door lock assembly RH.

    2. A01IJ9BC02
      *1 Active Lever
      *a

      Component without harness connected

      (Slide Door Lock Assembly RH)

      *b Direction of Release Operation
      *c Direction of Close Operation
      *d Neutral Release Switch ON Area
      *e Neutral Close Switch ON Area
      *f Neutral Position (Neutral Release Switch)
      *g Neutral Position (Neutral Close Switch)
      *h Neutral Area

      Check the resistance of the neutral switch.


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Neutral Close Switch
        Tester Connection Condition Specified Condition
        7 (E1) - 9 (NPC)

        Neutral position

        (neutral release switch)

        10 kΩ or higher
        7 (E1) - 9 (NPC)

        Neutral position

        (neutral close switch)

        10 kΩ or higher
        7 (E1) - 9 (NPC) Active lever is moved in direction of release operation 10 kΩ or higher
        7 (E1) - 9 (NPC) Active lever is moved in direction of close operation Below 1 Ω
        Standard Resistance
        Neutral Release Switch
        Tester Connection Condition Specified Condition
        7 (E1) - 8 (NPR)

        Neutral position

        (neutral release switch)

        10 kΩ or higher
        7 (E1) - 8 (NPR)

        Neutral position

        (neutral close switch)

        10 kΩ or higher
        7 (E1) - 8 (NPR) Active lever is moved in direction of release operation Below 1 Ω
        7 (E1) - 8 (NPR) Active lever is moved in direction of close operation 10 kΩ or higher

        If the result is not as specified, replace the slide door lock assembly RH.

    3. A01IFW6C02
      *a

      Component without harness connected

      (Slide Door Lock Assembly RH)

      *b Latch Open Position
      *c Half-latch Position
      *d Full-latch Position
      *e Over-latch Position

      Check the resistance of the latch switch and pole switch.


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Full Latch Switch
        Tester Connection Condition Specified Condition
        6 (FUL) - 7 (E1) Latch Open Below 1 Ω
        6 (FUL) - 7 (E1) Half-latch Below 1 Ω
        6 (FUL) - 7 (E1) Full-latch 10 kΩ or higher
        6 (FUL) - 7 (E1) Over-latch 10 kΩ or higher
        Standard Resistance
        Half Latch Switch
        Tester Connection Condition Specified Condition
        5 (HAF) - 7 (E1) Latch Open Below 1 Ω
        5 (HAF) - 7 (E1) Half-latch 10 kΩ or higher
        5 (HAF) - 7 (E1) Full-latch 10 kΩ or higher
        5 (HAF) - 7 (E1) Over-latch 10 kΩ or higher
        Standard Resistance
        Pole Switch
        Tester Connection Condition Specified Condition
        7 (E1) - 10 (POL) Open Below 1 Ω
        7 (E1) - 10 (POL) Between open and half-latch 10 kΩ or higher → Below 1 Ω
        7 (E1) - 10 (POL) Half-latch 10 kΩ or higher
        7 (E1) - 10 (POL) Between half-latch and full-latch 10 kΩ or higher → Below 1 Ω
        7 (E1) - 10 (POL) Full-latch 10 kΩ or higher
        7 (E1) - 10 (POL) Over-latch 10 kΩ or higher

        If the result is not as specified, replace the slide door lock assembly RH.