DATA LIST
Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.
Note
In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.
Connect the GTS to the DLC3.
Turn the engine switch on (IG).
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Data List.
Check the value(s) by referring to the table below.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Room Temperature Sensor | Cooler thermistor (room temperature sensor) | Min.: -6.50°C (-20.30°F) Max.: 57.25°C (135.05°F) |
Actual ambient temperature displayed | Cooler thermistor (room temperature sensor) system malfunction:
|
| Ambient Temp Sensor | Thermistor assembly (ambient temperature sensor) | Min.: -30.80°C (-23.44°F) Max.: 50.80°C (123.44°F) |
Actual ambient temperature displayed | Thermistor assembly (ambient temperature sensor) system malfunction:
|
| Adjusted Ambient Temp | Adjusted ambient temperature | Min.: -30.80°C (-23.44°F) Max.: 50.80°C (123.44°F) |
- | Air conditioning amplifier assembly malfunction |
| Evaporator Fin Thermistor | No. 1 cooler thermistor (evaporator temperature sensor) | Min.: -29.70°C (-21.46°F) Max.: 59.55°C (139.19°F) |
Actual evaporator temperature displayed | No. 1 cooler thermistor (evaporator temperature sensor) system malfunction:
|
| Evaporator Target Temp | Evaporator target temperature | Min.: -327.68°C (-557.82°F) Max.: 327.67°C (621.81°F) |
Evaporator target temperature displayed | No. 1 cooler thermistor (evaporator temperature sensor) system malfunction:
|
| Engine Coolant Temp | Engine coolant temperature sensor | Min.: 1.30°C (34.34°F) Max.: 90.55°C (194.99°F) |
Actual engine coolant temperature displayed |
|
| Blower Motor Speed Level | Blower with fan motor sub-assembly speed level | Min.: 0 Max.: 31 |
Displayed speed level increases in range between 0 and 31 as blower with fan motor sub-assembly speed increases | Blower with fan motor sub-assembly system malfunction |
| Emission Gas Nox Sensor | Emission gas (NOx) | Min.: 0 Max.: 255 |
Smog ventilation sensor value increases as gas amount increases | Smog ventilation sensor malfunction (emission gas [NOx] detected) |
| Emission Gas Sensor | Emission gas (HC, CO) | Min.: 0 Max.: 255 |
Smog ventilation sensor value increases as gas amount increases | Smog ventilation sensor malfunction (emission gas [HC, CO] detected) |
| Regulator Pressure Sensor | Air conditioner pressure sensor | Min.: -0.4566 MPaG Max.: 3.2943 MPaG |
Actual pressure displayed |
|
| Regulator Control Current | Solenoid valve control current | Min.: 0 A Max.: 0.997 A |
Value changes between 0 A and 0.997 A in accordance with solenoid valve operation | - |
| Room Temp Sensor (Rear) | Cooler thermistor (No. 2 room temperature sensor) | Min.: -6.50°C (-20.30°F) Max.: 57.25°C (135.05°F) |
Actual ambient temperature displayed | Cooler thermistor (No. 2 room temperature sensor) system malfunction:
|
| Evap Temp Sensor (Rear) | No. 2 air conditioning harness assembly (rear evaporator temperature sensor) | Min.: -29.70°C (-21.46°F) Max.: 59.55°C (139.19°F) |
Actual evaporator temperature displayed | No. 2 air conditioning harness assembly (rear evaporator temperature sensor) system malfunction:
|
| Blower Motor Level (Rear) | Rear blower with fan motor sub-assembly speed level | Min.: 0 Max.: 31 |
Displayed speed level increases in range between 0 and 31 as rear blower with fan motor sub-assembly speed increases | Rear blower with fan motor sub-assembly system malfunction |
| Air Outlet Servo Pulse (R) | No. 2 rear cooling unit damper servo sub-assembly (rear mode) target pulse | Min.: 128 Max.: 383 |
FACE: 276 (pulse) B/L: 228 (pulse) FOOT: 200 (pulse) |
|
| Air Outlet Servo Actual Pls(R) | No. 2 rear cooling unit damper servo sub-assembly (rear mode) actual pulse | Min.: 128 Max.: 383 |
FACE: 276 (pulse) B/L: 228 (pulse) FOOT: 200 (pulse) |
|
| Air Mix Servo Targ Pulse(R) | No. 1 rear cooling unit damper servo sub-assembly (rear air mix) target pulse | Min.: 128 Max.: 383 |
MAX. COLD: 254 (pulse) MAX. HOT: 299 (pulse) |
|
| Air Mix Servo Actual Pulse(R) | No. 1 rear cooling unit damper servo sub-assembly (rear air mix) actual pulse | Min.: 128 Max.: 383 |
MAX. COLD: 254 (pulse) MAX. HOT: 299 (pulse) |
|
| Air Mix Servo Targ Pulse(D) | No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) target pulse | Min.: 128 Max.: 383 |
for LHD:
for RHD: |
|
| Air Mix Servo Actual Pulse(D) | No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) actual pulse | Min.: 128 Max.: 383 |
for LHD:
for RHD: |
|
| Air Mix Servo Targ Pulse(P) | No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) target pulse | Min.: 128 Max.: 383 |
for LHD:
for RHD: |
|
| Air Mix Servo Actual Pulse(P) | No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) actual pulse | Min.: 128 Max.: 383 |
for LHD:
for RHD: |
|
| Air Outlet Servo Pulse (D) | No. 1 air conditioning radiator damper servo sub-assembly (front mode) target pulse | Min.: 128 Max.: 383 |
Single Seat Mode: 234 (pulse) FACE: 256 (pulse) B/L: 267 (pulse) FOOT-A: 288 (pulse) FOOT-R(F): 297 (pulse) FOOT-D: 305 (pulse) FOOT/DEF: 320 (pulse) DEF: 348 (pulse) |
|
| Air Outlet Servo Actu Pulse(D) | No. 1 air conditioning radiator damper servo sub-assembly (front mode) actual pulse | Min.: 128 Max.: 383 |
Single Seat Mode: 234 (pulse) FACE: 256 (pulse) B/L: 267 (pulse) FOOT-A: 288 (pulse) FOOT-R(F): 297 (pulse) FOOT-D: 305 (pulse) FOOT/DEF: 320 (pulse) DEF: 348 (pulse) |
|
| Air Inlet Damper Targ Pulse | No. 1 blower damper servo sub-assembly (recirculation) target pulse | Min.: 128 Max.: 383 |
for LHD:
for RHD: |
No. 1 blower damper servo sub-assembly (recirculation) system malfunction |
| Air Inlet Damper Actual Pulse | No. 1 blower damper servo sub-assembly (recirculation) actual pulse | Min.: 128 Max.: 383 |
for LHD:
for RHD: |
No. 1 blower damper servo sub-assembly (recirculation) system malfunction |
| Electric Heater Count | Maximum electric heater operation level | Min.: 0 Max.: 3 |
Maximum possible operation of electric heater displayed | PTC heater system malfunction (w/ PTC Heater) |
| Electric Heater Active Level | Actual electric heater operation level | Min.: 0 Max.: 3 |
Actual operation level of electric heater displayed | PTC heater system malfunction (w/ PTC Heater) |
| Shift Set Temperature | Shift set temperature | 2C decr, 1C decr, Normal, 1C incr, 2C incr | Customized value displayed | - |
| Air Inlet Mode | Air inlet mode | Auto or Manual | Customized value displayed | - |
| Compressor Mode | Compressor mode | Auto or Manual | Customized value displayed | |
| Evaporator Control | Evaporator control | Auto or Manual | Customized value displayed | - |
| Emission Gas Sensor Shift | Emission gas sensor shift | Mu Less, Less, Li Less, Normal, Li More, More, Mu More | Customized value displayed | - |
| ECO MODE Cancel | ECO run cancel switch input signal | ON or OFF | Customized value displayed | - |
| ECO Switch | ECO mode switch input signal | ON or OFF | Customized value displayed | - |
| Refrigerant Shortage Check | Refrigerant gas volume check | ON or OFF | Customized value displayed | - |
| Fan speed increment control | Fan speed increment control | Slow, Normal, Fast | Customized value displayed | - |
| Foot/DEF Auto Mode | Foot/DEF auto mode | ON or OFF | Customized value displayed | - |
| Foot/DEF Auto Blow Up | Foot/DEF auto blower speed increase | ON or OFF | Customized value displayed | - |
| Ambient Temperature Shift | Ambient temperature shift | 3C decr, 2C decr, 1C decr, Normal, 1C incr, 2C incr, 3C incr | Customized value displayed | - |
| A/C Cutoff Signal | The ECM sends the air conditioning control cut-off signal to the air conditioning amplifier assembly via CAN communication. | OFF or ON | OFF: The ECM does not send the air conditioning control cut-off signal ON: The ECM sends the air conditioning control cut-off signal |
SFI system malfunction |
| Refrigerant Gas Type | Refrigerant gas type | R134a or 1234yf | Refrigerant gas type displayed | - |
| Set Temperature (D Side) | Driver side set temperature | Min.: MAX COLD Max.: MAX HOT |
Driver side set temperature displayed |
|
| Set Temperature (P Side) | Front passenger side set temperature | Min.: MAX COLD Max.: MAX HOT |
Front passenger side set temperature displayed |
|
| Set Temperature (Rear) | Rear side set temperature | Min.: MAX COLD Max.: MAX HOT |
Rear side set temperature displayed |
|
| Operation Limitation Control History Count (Level1) | History of battery voltage drop in the past | Min.: 0 Max.: 255 |
Number of times battery voltage dropped in the past displayed | Counted when voltage drops below the specified level due to over discharge while driving. Tech Tips Clear control history after check |
| Operation Limitation Control History Count (Level2) | History of battery voltage drop in the past | Min.: 0 Max.: 255 |
Number of times battery voltage dropped in the past displayed | Counted when voltage drops below the specified level due to over discharge while driving. Tech Tips Clear control history after check |
| Outside Air Mode Auto Switch Function | Switches ON/OFF the function to switch the suction opening to the outside air mode automatically when the engine switch is turned off | OFF or ON | Customized value displayed | - |
| Number of Trouble Codes | Number of trouble codes | Min.: 0 Max.: 255 |
Number of DTCs displayed | - |
ACTIVE TEST
Using the GTS to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.
Connect the GTS to the DLC3.
Turn the engine switch on (IG).
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Active Test.
Check the operation by referring to the table below.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Blower Motor | Blower motor with fan sub-assembly | Min.: 0 Max.: 31 |
- |
| Magnetic Clutch Relay | Magnet clutch relay | OFF/ON |
|
| Heater Active Level | Quick heater assembly | Min.: 0 Max.: 3 |
Operates with the engine started and the vehicle stopped (w/ PTC Heater) |
| Air Mix Servo Targ Pulse(D) | No. 2 air conditioning radiator damper servo sub-assembly (driver side air mix) target pulse | Min.: 128 Max.: 383 |
for LHD:
for RHD: |
| Air Mix Servo Targ Pulse(P) | No. 2 air conditioning radiator damper servo sub-assembly (front passenger side air mix) target pulse | Min.: 128 Max.: 383 |
for LHD:
for RHD: |
| Air Outlet Servo Pulse (D) | No. 2 air conditioning radiator damper servo sub-assembly (front mode) pulse | Min.: 128 Max.: 383 |
Operates between 234 to 348 pulses |
| Air Inlet Damper Targ Pulse | No. 1 blower damper servo sub-assembly (recirculation) target pulse | Min.: 128 Max.: 383 |
Operates between 235 and 258 pulses |
| Rear Blower Motor | Cooling unit with fan motor sub-assembly | Min.: 0 Max.: 31 |
- |
| Rear Air Mix Servo Targ Pulse | No. 1 rear cooling unit damper servo motor sub-assembly (rear air mix) target pulse | Min.: 128 Max.: 383 |
Operates between 254 and 299 pulses |
| A/O Servo Pulse(Rr D) | No. 2 rear cooling unit damper servo motor sub-assembly (rear mode) pulse | Min.: 128 Max.: 383 |
Operates between 200 and 276 pulses |
| Ion Generator | Ion generator | OFF/ON | w/ Ion Generator |