AIR CONDITIONING SYSTEM, Diagnostic DTC:B1412/12

DTC Code DTC Name
B1412/12 Ambient Temperature Sensor Circuit

DESCRIPTION

The thermistor assembly (ambient temperature sensor) is installed in front of the condenser to detect the ambient temperature which is used to control the air conditioning system AUTO mode. This sensor is connected to the air conditioning amplifier assembly and detects fluctuations in the ambient temperature. This data is used for controlling the cabin temperature. The sensor sends a signal to the air conditioning amplifier assembly. The resistance of the thermistor assembly (ambient temperature sensor) changes in accordance with the ambient temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.

The air conditioning amplifier assembly applies a voltage (5 V) to the thermistor assembly (ambient temperature sensor) and reads voltage changes due to changes in the resistance of the thermistor assembly (ambient temperature sensor). The combination meter assembly sends the read signal to the air conditioning amplifier via CAN communication.

DTC No. Detection Item DTC Detection Condition Trouble Area Memory Note
B1412/12 Ambient Temperature Sensor Circuit
  • Diagnosis condition: None

  • Malfunction state: Open or short in thermistor assembly (ambient temperature sensor) circuit

  • Malfunction period: None (as present malfunction), memorized (4 seconds or more) (as past malfunction)


  • Thermistor assembly (ambient temperature sensor)

  • Harness or connector

  • Air conditioning amplifier assembly

  • Combination meter assembly

Memorized (4 seconds or more) -

Tech Tips


  • The air conditioning amplifier assembly stores the DTC of the respective malfunction if it has occurred for the period of time indicated in the parentheses.

  • If the ambient temperature is approximately -52.9°C (-63.22°F) or less, DTC B1412/12 may be output even though the system is normal.

WIRING DIAGRAM

B006MEGE10
*a Thermistor Assembly (Ambient Temperature Sensor)
*b Air Conditioning Amplifier Assembly

CAUTION / NOTICE / HINT

Note

When the battery is disconnected or the air conditioning amplifier assembly is replaced, be sure to perform servo motor initialization.

Click here

PROCEDURE


  1. READ VALUE USING GTS (AMBIENT TEMP SENSOR)


    1. Connect the GTS to the DLC3.

    2. Turn the engine switch on (IG).

    3. Turn the GTS on.

    4. Enter the following menus: Body Electrical / Air Conditioner / Data List.

    5. Check the value(s) by referring to the table below.


      Body Electrical > Air Conditioner > Data List
      Tester Display Measurement Item Range Normal Condition Diagnostic Note
      Ambient Temp Sensor Thermistor assembly (ambient temperature sensor)

      Min.: -30.80°C (-23.44°F)

      Max.: 50.80°C (123.44°F)

      Actual ambient temperature displayed

      Thermistor assembly (ambient temperature sensor) system malfunction:


      • When open circuit: -30.80°C (-23.44°F)

      • When short circuit: 50.80°C (123.44°F)


      Body Electrical > Air Conditioner > Data List
      Tester Display
      Ambient Temp Sensor
      OK
      The display is as specified in the normal condition column.
      Result
      Result Proceed to
      OK (When troubleshooting according to the DTC) A
      OK (When troubleshooting according to Problem Symptoms Table) B
      NG C

    A
    B
    C
  2. INSPECT THERMISTOR ASSEMBLY (AMBIENT TEMPERATURE SENSOR)


    1. Remove the thermistor assembly (ambient temperature sensor).

      Click here

    2. Inspect the thermistor assembly (ambient temperature sensor).

      Click here

      Result
      Proceed to
      OK
      NG

    NG
    OK
  3. CHECK HARNESS AND CONNECTOR (THERMISTOR ASSEMBLY [AMBIENT TEMPERATURE SENSOR] - AIR CONDITIONING AMPLIFIER ASSEMBLY)


    1. Disconnect the A14 thermistor assembly (ambient temperature sensor) connector.

    2. Disconnect the G36 air conditioning amplifier assembly connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      A14-1 - G36-5 (TAM) Always Below 1 Ω
      A14-2 - G36-13 (SG-2) Always Below 1 Ω
      A14-1 - A14-2 Always 10 kΩ or higher
      A14-1 or G36-5 (TAM) - Body ground Always 10 kΩ or higher
      A14-2 or G36-13 (SG-2) - Body ground Always 10 kΩ or higher
      Result
      Proceed to
      OK
      NG

    OK
    NG