| DTC Code | DTC Name |
|---|---|
| B1411/11 | Room Temperature Sensor Circuit |
DESCRIPTION
The cooler thermistor (room temperature sensor) is installed in the instrument panel to detect the cabin temperature which is used to control the heater and air conditioning system AUTO mode. The resistance of the cooler thermistor (room temperature sensor) changes in accordance with the cabin temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The air conditioning amplifier assembly applies a voltage (5 V) to the cooler thermistor (room temperature sensor) and reads voltage changes due to changes in the resistance of the cooler thermistor (room temperature sensor).
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Memory | Note |
|---|---|---|---|---|---|
| B1411/11 | Room Temperature Sensor Circuit | Open or short in cooler thermistor (room temperature sensor) circuit |
|
Memorized (4 seconds or more) | - |
Tech Tips
The air conditioning amplifier assembly stores the DTC of the respective malfunction if it has occurred for the period of time indicated in the parentheses.
If the cabin temperature is approximately -18.6°C (-1.48°F) or less, DTC B1411/11 may be output even though the system is normal.
WIRING DIAGRAM
| *a | Cooler Thermistor (Room Temperature Sensor) |
| *b | Air Conditioning Amplifier Assembly |
CAUTION / NOTICE / HINT
Note
When the battery is disconnected or the air conditioning amplifier assembly is replaced, be sure to perform servo motor initialization.
PROCEDURE
READ VALUE USING GTS (ROOM TEMPERATURE SENSOR)
Connect the GTS to the DLC3.
Turn the engine switch on (IG).
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Data List.
Check the value(s) by referring to the table below.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Room Temperature Sensor | Cooler thermistor (room temperature sensor) | Min.: -6.50°C (-20.30°F) Max.: 57.25°C (135.05°F) |
Actual ambient temperature displayed | Cooler thermistor (room temperature sensor) system malfunction:
|
| Tester Display |
|---|
| Room Temperature Sensor |
| OK |
|---|
| The display is as specified in the normal condition column. |
| Result | ||||||||
|---|---|---|---|---|---|---|---|---|
|
| A |
|
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY for LHD: Click here for RHD: Click here |
| B |
|
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE Click here |
| C |
|
INSPECT COOLER THERMISTOR (ROOM TEMPERATURE SENSOR)
Remove the cooler thermistor (room temperature sensor).
for LHD: Click here
for RHD: Click here
Inspect the cooler thermistor (room temperature sensor).
for LHD: Click here
for RHD: Click here
| Result | |||
|---|---|---|---|
|
| NG |
|
REPLACE COOLER THERMISTOR (ROOM TEMPERATURE SENSOR) for LHD: Click here for RHD: Click here |
| OK |
|
CHECK HARNESS AND CONNECTOR (COOLER THERMISTOR [ROOM TEMPERATURE SENSOR] - AIR CONDITIONING AMPLIFIER ASSEMBLY)
Disconnect the G28 cooler thermistor (room temperature sensor) connector.
Disconnect the G36 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| OK |
|
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY for LHD: Click here for RHD: Click here |
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |