BATTERY CURRENT SENSOR INSPECTION

PROCEDURE


  1. CHECK BATTERY CURRENT SENSOR ASSEMBLY


    1. Check the resistance of the current sensor.


      1. B006MTXC03
        *a

        Component without harness connected

        (Battery Current Sensor Assembly)

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        2 (VC5) - 4 (E2) Always 0.1 to 10 kΩ
        2 (VC5) - 3 (IB) Below 0.5 kΩ
        3 (IB) - 4 (E2) 0.05 to 10 kΩ

        If the result is not as specified, replace the battery current sensor assembly.

    2. Check the resistance of the thermistor.


      1. B006MTXC09
        *a

        Component without harness connected

        (Battery Current Sensor Assembly)

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        1 (THB) - 4 (E2) 20 to 30 °C (68 to 86 °F) 1.5 to 2.5 kΩ

        If the result is not as specified, replace the battery current sensor assembly.