SHIFT LEVER INSPECTION

PROCEDURE


  1. INSPECT SHIFT LOCK CONTROL UNIT ASSEMBLY

    Tech Tips

    If the results of the following inspections are as specified but a malfunction has occurred, replace the shift lock control unit assembly.


    1. Inspect wire harness:


      1. B006N5P

        Disconnect the shift lock control ECU connector.

      2. B006LWKC06
        *a

        Front view of wire harness connector

        (to Shift Lock Control ECU)

        Measure the voltage according to the value(s) in the table below.

        Standard Voltage
        Tester Connection Condition Specified Condition
        5 (IG) - Body ground Engine switch on (IG) 11 to 14 V
        Engine switch off Below 1 V
        4 (STP) - Body ground Brake pedal depressed 11 to 14 V
        Brake pedal released Below 1 V

        If the result is not as specified, repair or replace the shift lock control ECU wire harness.

      3. B006LWKC07
        *a

        Front view of wire harness connector

        (to Shift Lock Control ECU)

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Value
        1 (E) - Body ground Always Below 1 Ω

        If the result is not as specified, repair or replace the shift lock control ECU wire harness.

    2. Inspect shift lock solenoid:


      1. B006Q2S

        Disconnect the shift lock solenoid connector.

      2. B006N9AC02
        *a

        Front view of wire harness connector

        (to Shift Lock Solenoid)

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        4 (P) - 3 (E2) Shift lever in P 10 kΩ or higher
        Shift lever not in P Below 1 Ω

        If the result is not as specified, replace the shift lock control unit assembly.

        If the shift lock does not operate when the power source of the shift lock control unit assembly is normal and the resistance between the body ground and the shift lock solenoid is as specified, replace the shift lock control unit assembly.

      3. B006N9AC01
        *a

        Front view of wire harness connector

        (to Shift Lock Solenoid)

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        1 (SLS+) - 2 (SLS-) Always 112 Ω

        If the result is not as specified, replace the shift lock control unit assembly.

        If the shift lock does not operate when the power source of the shift lock control unit assembly is normal and the resistance between the body ground and the shift lock solenoid is as specified, replace the shift lock control unit assembly.

  2. INSPECT TRANSMISSION CONTROL SWITCH (for LHD)


    1. B006OHZ

      Disconnect the transmission control switch connector.

    2. B006KZXC30
      *a

      Component without harness connected

      (Transmission Control Switch (Shift Lock Control Unit Assembly))

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      4 (IG) - 5 (S) Shift lever in S, "+" or "-" Below 1 Ω
      Shift lever not in S, "+" or "-" 10 kΩ or higher
      3 (SFTU) - 2 (E)

      Shift lever held in "+"

      (Up shift)

      Below 1 Ω
      Shift lever not held in "+" 10 kΩ or higher
      1 (SFTD) - 2 (E)

      Shift lever held in "-"

      (Down shift)

      Below 1 Ω
      Shift lever not held in "-" 10 kΩ or higher

      If the result is not as specified, replace the shift lock control unit assembly.

  3. INSPECT TRANSMISSION CONTROL SWITCH (for RHD)


    1. B006O1Z

      Disconnect the transmission control switch connector.

    2. B006KZXC31
      *a

      Component without harness connected

      (Transmission Control Switch (Shift Lock Control Unit Assembly))

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      4 (IG) - 5 (S) Shift lever in S, "+" or "-" Below 1 Ω
      Shift lever not in S, "+" or "-" 10 kΩ or higher
      1 (SFTU) - 2 (E)

      Shift lever held in "+"

      (Up shift)

      Below 1 Ω
      Shift lever not held in "+" 10 kΩ or higher
      3 (SFTD) - 2 (E)

      Shift lever held in "-"

      (Down shift)

      Below 1 Ω
      Shift lever not held in "-" 10 kΩ or higher

      If the result is not as specified, replace the shift lock control unit assembly.