ATMOSPHERIC PRESSURE SENSOR INSTALLATION

PROCEDURE


  1. INSTALL ATMOSPHERIC PRESSURE SENSOR (VACUUM SENSOR ASSEMBLY)


    1. Install the atmospheric pressure sensor (vacuum sensor assembly) to the vacuum sensor bracket with the 2 nuts.

      Torque:
      5.0 N*m  { 51 kgf*cm, 44 in.*lbf }
    2. Install the atmospheric pressure sensor (vacuum sensor assembly) to the vehicle body with the bolt.

      Torque:
      8.0 N*m  { 82 kgf*cm, 71 in.*lbf }
    3. Connect the connector to the atmospheric pressure sensor (vacuum sensor assembly).

  2. INSTALL GLOVE COMPARTMENT DOOR STOPPER SUB-ASSEMBLY

    Click here

  3. INSTALL GLOVE COMPARTMENT DOOR ASSEMBLY

    Click here