Fail-safe
The fail-safe function minimizes the loss of operation when a malfunction occurs in a sensor or solenoid.
| Malfunctioning Part | Function |
|---|---|
| Input Speed Sensor NT | Shifting to only 1st or 3rd gear is allowed. |
| Output Speed Sensor NC |
|
| ATF Temp. Sensor | Shifting between 1st to 4th gear is allowed. |
| TCM Power Supply (Voltage is Low) | When the vehicle is being driven in 6th gear, the transaxle is fixed in 6th gear. When being driven in 1st to 5th gear, the transaxle is fixed in 5th gear. |
| CAN communication | Shifting to only 1st or 3rd gear is allowed. |
| Knock Sensor | Shifting between 1st to 4th gear is allowed. |
| Shift Solenoid Valve SL1, SL2, SL3 and SL4 | The current to the failed shift solenoid valve is cut off and operating the other shift solenoid valves with normal operation performs shift control. (Shift controls in fail-safe mode are described in the table on the next page. For details, refer to Fail-safe Control Chart.) |
| Gear | 1st | 2nd | 3rd | 4th | 5th | 6th | |
|---|---|---|---|---|---|---|---|
| Shift Solenoid Valve | SL1 | ON | ON | ON | ON | OFF | OFF |
| SL2 | OFF | OFF | OFF | ON | ON | ON | |
| SL3 | OFF | ON | OFF | OFF | OFF | ON | |
| SL4 | OFF | OFF | ON | OFF | ON | OFF | |
| Gear in Normal Conditions | 1st | 2nd | 3rd | 4th | 5th | 6th | |
|---|---|---|---|---|---|---|---|
| SL1 | ON Malfunction (without Fail-safe Control)* | 1st | 2nd | 3rd | 4th | 4th | 4th |
| OFF Malfunction (without Fail-safe Control) | 1st to N | 2nd to N | 3rd to N | 4th to N | 5th | 6th | |
| Fail-safe Control during OFF Malfunction | Fixed in 3rd or 5th | ||||||
| SL2 | ON Malfunction (without Fail-safe Control)* | 1st to 4th | 2nd to 4th | 3rd to 4th | 4th | 5th | 6th |
| OFF Malfunction (without Fail-safe Control) | 1st | 2nd | 3rd | 4th to 1st | 5th to N | 6th to N | |
| Fail-safe Control during OFF Malfunction | Fixed in 1st, 2nd or 3rd | ||||||
| SL3 | ON Malfunction (without Fail-safe Control)* | 1st to 2nd | 2nd | 3rd | 4th | 5th | 6th |
| OFF Malfunction (without Fail-safe Control) | 1st | 2nd to 1st | 3rd | 4th | 5th | 6th to N | |
| Fail-safe Control during OFF Malfunction | Fixed in 1st, 3rd, 4th or 5th | ||||||
| SL4 | ON Malfunction (without Fail-safe Control)* | 3rd | 3rd | 3rd | 4th | 5th | 5th |
| OFF Malfunction (without Fail-safe Control) | 1st | 2nd | 3rd to 1st | 4th | 5th to N | 6th | |
| Fail-safe Control during OFF Malfunction | Fixed in 1st, 2nd, 4th or 6th | ||||||