STOP AND START SYSTEM, Diagnostic DTC:P323B

DTC Code DTC Name
P323B Backup Boost Converter

DESCRIPTION

Refer to DTC B22C0

Click here

DTC No. Detection Item DTC Detection Condition Trouble Area Warning Indicate Memory
P323B Backup Boost Converter

Any of the following conditions are met for 1 second or more (1 trip detection logic):


  • BBC malfunction is detected

  • Engine stop and start ECU thermistor temperature is 128°C (262.4°F) or higher

  • Difference in temperature between thermistor 1 and thermistor 2 of the engine stop and start ECU is 40°C (104°F) or higher

  • B42, B43 voltage is 6.0 V or less and BBC is not overheating

  • IG41 voltage is 6.0 V or less


  • Engine stop and start ECU

  • Wire harness or connector

  • Battery

  • BBC NO. 1 fuse

  • BBC NO. 2 fuse

Blinks DTC stored

CONFIRMATION DRIVING PATTERN

Tech Tips

DTCs for the stop and start system are not cleared even if the malfunction has been repaired. After repairing the malfunction, be sure to clear the DTCs.

Click here


  1. Tech Tips


    • If the cable is disconnected from the negative (-) battery terminal, stop and start control is prohibited until refresh charge is completed. In this case, drive the vehicle approximately 5 to 40 minutes until refresh charge is completed and stop and start control operation is permitted.

    • Allow the engine to idle for 3 minutes after it is warmed up and check that the engine idle speed is within 50 rpm of the target idle speed.

    CONFIRMATION AFTER TROUBLESHOOTING


    1. Connect the GTS to the DLC3.

    2. Turn the engine switch on (IG) and turn the GTS on.

    3. Clear the DTCs.

      Click here


      Powertrain > Stop and Start > Clear DTCs
    4. Start the engine and warm it up.

    5. Drive the vehicle at 7 km/h (4.3 mph) or more.

      CAUTION:

      When performing Confirmation Driving Pattern, obey all speed limits and traffic laws.

    6. Depress the brake pedal and stop the vehicle.

    7. Keep the engine stopped by stop and start control for 1 second or more. (Keep the shift lever in D.)

    8. Release the brake pedal with the shift lever in D to start the engine.

      Tech Tips

      If the engine cranks slowly when the engine is restarted, it can be determined that the battery voltage is low.

    9. Check that DTCs are not output.

      Click here


      Powertrain > Stop and Start > Trouble Codes
  2. STOP AND START SYSTEM OPERATION CHECK

    Tech Tips

    If the cable is disconnected from the negative (-) battery terminal, stop and start control is prohibited until refresh charge is completed. In this case, drive the vehicle approximately 5 to 40 minutes until refresh charge is completed and stop and start control operation is permitted.


    1. Start the engine and warm it up.

    2. Turn the air conditioning system off.

    3. Drive the vehicle at 7 km/h (4.3 mph) or more.

      CAUTION:

      When performing Confirmation Driving Pattern, obey all speed limits and traffic laws.

    4. Depress the brake pedal and stop the vehicle.

    5. Allow the engine to stop by stop and start control. (Keep the shift lever in D.)

    6. Release the brake pedal with the shift lever in D to start the engine.

WIRING DIAGRAM

Click here

CAUTION / NOTICE / HINT

Note


  • When replacing the engine stop and start ECU with a new one, make sure to download the previous status (number of starter operations) of the old engine stop and start ECU. After replacing the engine stop and start ECU, turn the engine switch on (IG) and wait 20 seconds, then confirm that "OK" is displayed for the Data List item "Oper Prohibition (O/P Air Bleeding)". Then upload the previous status (number of starter operations) to the engine stop and start ECU.

    Click here

  • After replacing the engine stop and start ECU or air conditioning amplifier assembly, reset and perform learning of the air conditioning information in the engine stop and start ECU.

    Click here

  • After replacing the engine stop and start ECU or airbag ECU assembly, clear and calibrate the deceleration sensor zero point in the engine stop and start ECU.

    Click here

  • Inspect the fuses for circuits related to this system before performing the following procedure.

Tech Tips

Using the GTS, read the freeze frame data before troubleshooting. System condition information is recorded as freeze frame data the moment a DTC is stored. This information can be useful when troubleshooting.

Click here

PROCEDURE


  1. CHECK HARNESS AND CONNECTOR (ENGINE STOP AND START ECU - BBC NO. 1, BBC NO. 2 FUSES)


    1. Disconnect the A59 engine stop and start ECU connector.

    2. Remove the BBC NO. 1 fuse from No. 1 engine room relay block.

    3. Remove the BBC NO. 2 fuse from No. 1 engine room relay block.

    4. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      A59-1 (BIN2) - BBC NO. 2 fuse terminal 2 Always Below 1 Ω
      A59-3 (BIN1) - BBC NO. 1 fuse terminal 2 Always Below 1 Ω
      A59-1 (BIN2) - Body ground Always 10 kΩ or higher
      A59-3 (BIN1) - Body ground Always 10 kΩ or higher
      BBC NO. 2 fuse terminal 2 - Body ground Always 10 kΩ or higher
      BBC NO. 1 fuse terminal 2 - Body ground Always 10 kΩ or higher
      Result
      Proceed to
      OK
      NG

    NG
    OK
  2. CHECK HARNESS AND CONNECTOR (ENGINE STOP AND START ECU POWER SOURCE CIRCUIT)


    1. A01UEH1C01
      *a

      Front view of wire harness connector

      (to Engine Stop and Start ECU)

      Disconnect the A59 and G50 engine stop and start ECU connectors.

    2. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      A59-1 (BIN2) - Body ground Always 9.5 to 14 V
      A59-3 (BIN1) - Body ground Always 9.5 to 14 V
    3. Turn the engine switch on (IG).

    4. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      G50-21 (IG1) - Body ground Engine switch on (IG) 9.5 to 14 V
      Result
      Proceed to
      OK
      NG

    NG
    OK
  3. CHECK HARNESS AND CONNECTOR (ENGINE STOP AND START ECU - BODY GROUND)


    1. Disconnect the A59 engine stop and start ECU connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      A59-2 (GND2) - Body ground Always Below 1 Ω
      A59-8 (GND1) - Body ground Always Below 1 Ω
      A60-6 (DGND) - Body ground Always Below 1 Ω
      Result
      Proceed to
      OK
      NG

    NG
    OK
  4. CHECK HARNESS AND CONNECTOR (ENGINE STOP AND START ECU - EACH ECU OR SENSOR)


    1. Disconnect the G50 engine stop and start ECU connector.

    2. Disconnect the G30 air conditioning control assembly connector.

    3. Disconnect the G59 clearance warning ECU assembly connector.

    4. Disconnect the S8 integration control and panel assembly connector.

    5. Disconnect the F1 navigation receiver assembly connector.

    6. Disconnect the S36 television display assembly connector.

    7. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      G50-3 (IG41) - G30-5 (IG+) Always Below 1 Ω
      G50-3 (IG41) - G59-1 (IG) Always Below 1 Ω
      G50-3 (IG41) - S8-7 (IG) Always Below 1 Ω
      G50-11 (B43) - G30-1 (+B) Always Below 1 Ω
      G50-12 (B42) - F1-4 (+B1) Always Below 1 Ω
      G50-12 (B42) - S36-1 (+B) Always Below 1 Ω
      G50-3 (IG41) - Body ground Always 10 kΩ or higher
      G50-11 (B43) - Body ground Always 10 kΩ or higher
      G50-12 (B42) - Body ground Always 10 kΩ or higher
      Result
      Proceed to
      OK
      NG

    OK
    NG