2GR-FE COOLING SERVICE DATA

Thermostat
Condition Specified Condition
Standard valve opening temperature 80 to 84°C (176 to 183°F)
Standard valve lift 10 mm (0.394 in.) or more at 95°C (203°F)
Cooling Fan Motor
Item Condition Specified Condition
Cooling fan motor Battery voltage applied at 20°C (68°F) 13.4 to 19.4 A
No. 2 cooling fan motor 13.4 to 19.4 A
Relay
Item Tester Connection Tester Connection Specified Condition
FAN NO. 1 relay 3 - 5 Battery voltage not applied between terminals 1 and 2 10 kΩ or higher
3 - 5 Battery voltage applied between terminals 1 and 2 Below 1 Ω
FAN NO. 2 relay 3 - 5 Battery voltage not applied between terminals 1 and 2 10 kΩ or higher
3 - 5 Battery voltage applied between terminals 1 and 2 Below 1 Ω
Radiator
Item Condition Specified Condition
Reserve tank cap

Standard pressure

(for brand-new reserve tank cap)

93 to 123 kPa (0.9 to 1.3 kgf/cm2, 13.5 to 18.0 psi)

Minimum pressure

(for used reserve tank cap)

79 kPa (0.8 kgf/cm2, 11.5 psi)

Coolant
Capacity Classification
10.6 liters (11.2 US qts, 9.3 Imp. qts) Use only "TOYOTA Super Long Life Coolant", or similar high quality ethylene glycol based non-silicate, non-amine, non-nitrite, and non-borate coolant with long-life hybrid organic acid technology (coolant with long-life hybrid organic acid technology is a combination of low phosphates and organic acids).