PROCEDURE
INSPECT OUTER MIRROR LH
| *a | Component without harness connected (Outer Mirror LH) |
w/ Mirror Heater:
Check the outer mirror heater operation.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the outer mirror LH.
w/ EC Mirror:
Check EC mirror operation.
Connect a new 1.5 V dry-cell battery.
| *a | Component without harness connected (Outer Mirror LH) |
Apply 1.5 V dry-cell battery to the terminals of the connector, and check that the EC mirror operation.
Note
Do not apply a voltage of higher than 1.5 V.
| OK | ||||
|---|---|---|---|---|
|
If the result is not as specified, replace the outer mirror LH.
w/ Blind Spot Monitor System:
Check the operation of the blind spot monitor indicator.
| *a | Component without harness connected (Outer Mirror LH) |
Connect 4 new 1.5 V dry-cell batteries in series.
Apply 6 V dry-cell batteries to the terminals of the connector, and check the blind spot monitor indicator condition.
| OK | ||||
|---|---|---|---|---|
|
If the result is not as specified, replace the outer mirror LH.
INSPECT OUTER MIRROR RH
| *a | Component without harness connected (Outer Mirror RH) |
w/ Mirror Heater:
Check the outer mirror heater operation.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the outer mirror RH.
w/ EC Mirror:
Check EC mirror operation.
Connect a new 1.5 V dry-cell battery.
| *a | Component without harness connected (Outer Mirror RH) |
Apply 1.5 V dry-cell battery voltage to the terminals of the connector, and check that the EC mirror operation.
Note
Do not apply a voltage of higher than 1.5 V.
| OK | ||||
|---|---|---|---|---|
|
If the result is not as specified, replace the outer mirror RH.
w/ Blind Spot Monitor System:
Check the operation of the blind spot monitor indicator.
| *a | Component without harness connected (Outer Mirror RH) |
Connect 4 new 1.5 V dry-cell batteries in series.
Apply 6 V dry-cell batteries to the terminals of the connector, and check the blind spot monitor indicator condition.
| OK | ||||
|---|---|---|---|---|
|
If the result is not as specified, replace the outer mirror RH.