PROCEDURE
RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM
REMOVE FAN AND GENERATOR V BELT
REMOVE NO. 1 ENGINE UNDER COVER ASSEMBLY
DISCONNECT DISCHARGE HOSE SUB-ASSEMBLY
Remove the bolt and disconnect the discharge hose sub-assembly.
Remove the O-ring from the discharge hose sub-assembly.
Note
Seal the openings of the disconnected parts using vinyl tape to prevent entry of moisture and foreign matter.
DISCONNECT SUCTION HOSE SUB-ASSEMBLY
Remove the bolt and disconnect the suction hose sub-assembly.
Remove the O-ring from the suction hose sub-assembly.
Note
Seal the openings of the disconnected parts using vinyl tape to prevent entry of moisture and foreign matter.
REMOVE COMPRESSOR ASSEMBLY WITH PULLEY
Disconnect the connector.
Detach the clamp and disconnect the wire harness.
Remove the 2 bolts and 2 nuts.
Using an E8 "TORX" socket wrench, remove the 2 stud bolts and compressor assembly with pulley.