AIR CONDITIONING SYSTEM DATA LIST / ACTIVE TEST


  1. DATA LIST

    Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.

    Note

    In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.


    1. Connect the GTS to the DLC3.

    2. Turn the engine switch on (IG).

    3. Turn the GTS on.

    4. Enter the following menus: Body Electrical / Air Conditioner / Data List.

    5. Check the value(s) by referring to the table below.


      Body Electrical > Air Conditioner > Data List
      Tester Display Measurement Item Range Normal Condition Diagnostic Note
      Room Temperature Sensor Cooler thermistor (room temperature sensor)

      Min.: -6.50°C (-20.30°F)

      Max.: 57.25°C (135.05°F)

      Actual ambient temperature displayed -
      Ambient Temp Sensor Thermistor assembly (ambient temperature sensor)

      Min.: -23.30°C (-9.94°F)

      Max.: 65.95°C (150.71°F)

      Actual ambient temperature displayed
      • Thermistor assembly (ambient temperature sensor) system malfunction:


        • When open circuit: -23.30°C

        • When short circuit: 65.95°C

      Adjusted Ambient Temp Adjusted ambient temperature

      Min.: -30.80°C (-23.44°F)

      Max.: 50.80°C (123.44°F)

      - -
      Evaporator Fin Thermistor No. 1 cooler thermistor (evaporator temperature sensor)

      Min.: -29.70°C (-21.46°F)

      Max.: 59.55°C (139.19°F)

      Actual evaporator temperature displayed -
      Evaporator Target Temp Evaporator target temperature

      Min.: -327.68°C (-557.82°F)

      Max.: 327.67°C (621.81°F)

      Evaporator target temperature displayed -
      Engine Coolant Temp Engine coolant temperature sensor

      Min.: 1.30°C (34.34°F)

      Max.: 90.55°C (194.99°F)

      Actual engine coolant temperature displayed -
      Blower Motor Speed Level Blower motor speed level

      Min.: 0

      Max.: 31

      Displayed speed level increases in range between 0 and 31 as blower motor speed increases -
      Regulator Pressure Sensor Air conditioner pressure sensor

      Min.: -66.22 psi (gauge)

      Max.: 477.68 psi (gauge)

      Actual refrigerant pressure displayed -
      Regulator Control Current Solenoid valve control current

      Min.: 0 A

      Max.: 0.997 A

      Value changes between 0 A and 0.997 A in accordance with solenoid valve operation -
      Air Outlet Servo Pulse (R) No. 2 air conditioning radiator damper servo sub-assembly target pulse

      Min.: 128

      Max.: 383

      FACE: 264 (pulse)

      B/L: 245 (pulse)

      FOOT: 208 (pulse)

      Foot/DEF: 208 (pulse)

      SHUT: 166 (pulse)

      -
      Air Outlet Servo Actual Pls(R) No. 2 air conditioning radiator damper servo sub-assembly actual pulse

      Min.: 128

      Max.: 383

      FACE: 264 (pulse)

      B/L: 245 (pulse)

      FOOT: 208 (pulse)

      Foot/DEF: 208 (pulse)

      SHUT: 166 (pulse)

      -
      Air Mix Servo Targ Pulse(D) No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) target pulse

      Min.: 128

      Max.: 383

      for LHD:

      MAX. COLD: 257 (pulse)

      MAX. HOT: 165 (pulse)

      for RHD:

      MAX. COLD: 255 (pulse)

      MAX. HOT: 347 (pulse)

      -
      Air Mix Servo Actual Pulse(D) No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) actual pulse

      Min.: 128

      Max.: 383

      for LHD:

      MAX. COLD: 257 (pulse)

      MAX. HOT: 165 (pulse)

      for RHD:

      MAX. COLD: 255 (pulse)

      MAX. HOT: 347 (pulse)

      -
      Air Mix Servo Targ Pulse(P) No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) target pulse

      Min.: 128

      Max.: 383

      for LHD:

      MAX. COLD: 255 (pulse)

      MAX. HOT: 347 (pulse)

      for RHD:

      MAX. COLD: 257 (pulse)

      MAX. HOT: 165 (pulse)

      -
      Air Mix Servo Actual Pulse(P) No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) actual pulse

      Min.: 128

      Max.: 383

      for LHD:

      MAX. COLD: 255 (pulse)

      MAX. HOT: 347 (pulse)

      for RHD:

      MAX. COLD: 257 (pulse)

      MAX. HOT: 165 (pulse)

      -
      Air Outlet Servo Pulse (D) No. 1 air conditioning radiator damper servo sub-assembly (mode) target pulse

      Min.: 128

      Max.: 383

      FACE: 256 (pulse)

      B/L: 267 (pulse)

      FOOT-0: 288 (pulse)

      FOOT-R(F): 297 (pulse)

      FOOT-D: 305 (pulse)

      FOOT/DEF: 320 (pulse)

      DEF: 348 (pulse)

      -
      Air Outlet Servo Actu Pulse(D) No. 1 air conditioning radiator damper servo sub-assembly (mode) actual pulse

      Min.: 128

      Max.: 383

      FACE: 256 (pulse)

      B/L: 267 (pulse)

      FOOT-0: 288 (pulse)

      FOOT-R(F): 297 (pulse)

      FOOT-D: 305 (pulse)

      FOOT/DEF: 320 (pulse)

      DEF: 348 (pulse)

      -
      Air Inlet Damper Targ Pulse No. 1 blower damper servo sub-assembly target pulse

      Min.: 128

      Max.: 383

      RECIRCULATION: 258 (pulse)

      FRESH: 235 (pulse)

      -
      Air Inlet Damper Actual Pulse No. 1 blower damper servo sub-assembly actual pulse

      Min.: 128

      Max.: 383

      RECIRCULATION: 258 (pulse)

      FRESH: 235 (pulse)

      -
      Electric Heater Count Maximum electric heater operation level

      Min.: 0

      Max.: 3

      Maximum possible operation of electric heater displayed w/ PTC Heater
      Electric Heater Active Level Actual electric heater operation level

      Min.: 0

      Max.: 3

      Actual operation level of electric heater displayed w/ PTC Heater
      Shift Set Temperature Shift set temperature 2C decr, 1C decr, Normal, 1C incr, 2C incr Customized value displayed -
      Air Inlet Mode Air inlet mode Auto or Manual Customized value displayed -
      Compressor Mode Compressor mode Auto or Manual Customized value displayed -
      Evaporator Control Evaporator control Auto or Manual Customized value displayed -
      ECO MODE Cancel ECO run cancel switch input signal ON or OFF Customized value displayed -
      ECO Switch Integration control and panel assembly (ECO mode switch) ON or OFF

      ON: Integration control and panel assembly (ECO mode switch) being turned and held at ECO position

      OFF: Integration control and panel assembly (ECO mode switch) not turned

      -
      Refrigerant Shortage Check Refrigerant gas volume check ON or OFF Customized value displayed -
      Fan speed increment control Fan speed increment control Slow, Normal, Fast Customized value displayed -
      Foot/DEF Auto Mode Foot/DEF Auto Mode ON or OFF Customized value displayed -
      Foot/DEF Auto Blow Up Foot/DEF Auto blower speed increase ON or OFF Customized value displayed -
      Ambient Temperature Shift Ambient temperature shift 3C decr, 2C decr, 1C decr, Normal, 1C incr, 2C incr, 3C incr Customized value displayed -
      A/C Cutoff Signal A/C control cutoff signal OFF or ON

      A/C switch on: OFF

      A/C switch off: ON

      -
      Refrigerant Gas Type Refrigerant gas type R134a or 1234yf Refrigerant gas type displayed -
      Blower Operation Setting (Stop&Start) Blower level to be 1, when Stop and Start control operate Blower off, Blower Level1 Customized valve displayed -
      Set Temperature (D Side) Driver side set temperature

      Min.: MAX COLD

      Max.: MAX HOT

      Driver side set temperature displayed -
      Set Temperature (P Side) Front passenger side set temperature

      Min.: MAX COLD

      Max.: MAX HOT

      Front passenger side set temperature displayed -
      Operation Limitation Control History Count (Level1) History of battery voltage drop in the past

      Min.: 0

      Max.: 255

      Number of times battery voltage dropped in the past displayed

      Counted when voltage drops below the specified level due to over discharge while driving.

      Tech Tips

      Clear control history after check

      Operation Limitation Control History Count (Level2) History of battery voltage drop in the past

      Min.: 0

      Max.: 255

      Number of times battery voltage dropped in the past displayed

      Counted when voltage drops below the specified level due to over discharge while driving.

      Tech Tips

      Clear control history after check

      Outside Air Mode Auto Switch Function Switches ON/OFF the function to switch the suction opening to the outside air mode automatically when the engine switch is turned off OFF or ON Customized value displayed -
      Number of Trouble Codes Number of trouble codes

      Min.: 0

      Max.: 255

      Number of DTCs displayed -
  2. ACTIVE TEST

    Using the GTS to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.


    1. Connect the GTS to the DLC3.

    2. Turn the engine switch on (IG).

    3. Turn the GTS on.

    4. Enter the following menus: Body Electrical / Air Conditioner / Active Test.

    5. Check the operation by referring to the table below.


      Body Electrical > Air Conditioner > Active Test
      Tester Display Measurement Item Control Range Diagnostic Note
      Blower Motor Blower with fan motor sub-assembly

      Min.: 0

      Max.: 31

      -
      Magnetic Clutch Relay Magnet clutch relay OFF, ON Operate with engine starts and the vehicle stopped
      Defogger Relay (Rear) Defogger relay (engine room junction block assembly) OFF, ON -
      Heater Active Level

      Quick heater assembly

      (w/ PTC Heater)

      Min.: 0, Max.: 3 Operate with engine starts and the vehicle stopped
      Air Mix Servo Targ Pulse(D) No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) pulse

      Min.: 128

      Max.: 383

      for LHD:

      Operates between 165 and 257 pulse

      for RHD:

      Operates between 255 and 347 pulses

      Air Mix Servo Targ Pulse(P) No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) pulse

      Min.: 128

      Max.: 383

      for LHD:

      Operates between 255 and 347 pulse

      for RHD:

      Operates between 165 and 257 pulses

      Air Outlet Servo Pulse (D) No. 1 air conditioning radiator damper servo sub-assembly (mode) pulse

      Min.: 128

      Max.: 383

      Operates between 256 and 348 pulses
      Air Inlet Damper Targ Pulse No. 1 blower damper servo sub-assembly target pulse

      Min.: 128

      Max.: 383

      Operates between 235 and 258 pulses
      A/O Servo Pulse(Rr D) No. 2 air conditioning radiator damper servo sub-assembly target pulse

      Min.: 128

      Max.: 383

      Operates between 166 and 264 pulses