TRIP SWITCH INSPECTION

PROCEDURE


  1. INSPECT TRIP SWITCH (for LHD)

    A01HDSOC06
    *1 ODO TRIP Switch
    *a

    Component without harness connected

    (Trip Switch)


    1. Check the resistance.

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      4 (A/B) - 5 (E) ODO TRIP switch on (Pushed) Below 1 Ω
      ODO TRIP switch off (Not pushed) 10 kΩ or higher

      If the result is not as specified, replace the trip switch.

    2. A01HDSOC05
      *a

      Component without harness connected

      (Trip Switch)

      Check the illumination.

      Apply battery voltage to the connector and check the illumination condition.

      OK
      Measurement Condition Specified Condition

      Battery positive (+) → Terminal 1 (ILL+)

      Battery negative (-) → Terminal 3 (ILL-)

      Illuminates

      If the result is not as specified, replace the trip switch.

  2. INSPECT TRIP SWITCH (for RHD)


    1. A01HDVJC08
      *1 ODO TRIP Switch
      *a

      Component without harness connected

      (Trip Switch)

      Check the resistance.

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      4 (A/B) - 5 (E) ODO TRIP switch on (Pushed) Below 1 Ω
      ODO TRIP switch off (Not pushed) 10 kΩ or higher

      If the result is not as specified, replace the trip switch.

    2. A01HDVJC07
      *a

      Component without harness connected

      (Trip Switch)

      Check the illumination.

      Apply battery voltage to the connector and check the illumination condition.

      OK
      Measurement Condition Specified Condition

      Battery positive (+) → Terminal 1 (ILL+)

      Battery negative (-) → Terminal 3 (ILL-)

      Illuminates

      If the result is not as specified, replace the trip switch.