DOOR CONTROL SWITCH INSPECTION

PROCEDURE


  1. INSPECT DOOR CONTROL SWITCH ASSEMBLY


    1. A01HEMZC02
      *a

      Component without harness connected

      (Door Control Switch Assembly)

      *b Lock
      *c Unlock

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      4 (L) - 5 (E) Lock Below 1 Ω

      4 (L) - 5 (E)

      2 (UL) - 5 (E)

      Off 10 kΩ or higher
      2 (UL) - 5 (E) Unlock Below 1 Ω

      If the result is not as specified, replace the door control switch assembly.

    2. Check that the LED illuminates.


      1. Apply battery voltage to the door control switch assembly and check that the LED illuminates.

        OK
        Measurement Condition Specified Condition

        Battery positive (+) → 3 (ILL+)

        Battery negative (-) → 1 (ILL-)

        LED illuminates

        If the result is not as specified, replace the door control switch assembly.