PROCEDURE
INSTALL MULTIPLEX NETWORK BODY ECU (MAIN BODY ECU)
Note
Make sure that no foreign matter gets on the connecting surfaces.
Do not touch the multiplex network body ECU (main body ECU) connector and instrument panel junction block assembly connector.
| *a | 20° |
|
Housing Sidewall |
Insert the multiplex network body ECU (main body ECU) up to the position where it contacts the housing sidewall of the guide as shown in the illustration.
Tech Tips
Make sure to keep the angle 20° or more as shown in the illustration.
|
Slide |
|
Housing Sidewall |
Slide the multiplex network body ECU (main body ECU) along the housing sidewall so that it attaches to the 2 guides.
| *1 | Side A Contact Portion |
While keeping the multiplex network body ECU (main body ECU) in contact with side A of the junction block (axis of rotation), rotate it downward as shown in the illustration.
|
Push Area |
Press the push area until the claw engages to install the multiplex network body ECU (main body ECU).
Note
Make sure to press only the push area.
Confirm the engagement of the multiplex network body ECU (main body ECU) and junction block by listening for the lock sound.
Tech Tips
If a lock sound cannot be heard, visually check the lock part engagement. The engagement can also be confirmed if the multiplex network body ECU (main body ECU) and junction block are flush.
INSTALL INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY
Connect the 3 connectors to the multiplex network body ECU (main body ECU).
Install the instrument panel junction block assembly with the bolt and 2 nuts.
Connect the lower side of the instrument panel junction block assembly connector.
| *A | w/ Connector Stopper |
| *1 | Connector Stopper |
w/o Connector Stopper:
Connect the connector and lock the connector lock lever.
Tech Tips
Use the same procedure to connect the remaining 3 connectors.
w/ Connector Stopper:
Connect the connector and lock the connector lock lever.
Tech Tips
Use the same procedure to connect the remaining 3 connectors.
Attach the claw to lock the connector stopper.
Attach the 4 wire harness clamps.
INSTALL ENGINE STOP AND START ECU
INSTALL NO. 2 INSTRUMENT PANEL UNDER COVER SUB-ASSEMBLY
INSTALL GLOVE COMPARTMENT DOOR ASSEMBLY
CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
Note