PROCEDURE
PRECAUTION
Note
After turning the engine switch off, waiting time may be required before disconnecting the cable from the battery terminal. Therefore, make sure to read the disconnecting the cable from the battery terminal notice before proceeding with work.
DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL
Note
When disconnecting the cable, some systems need to be initialized after the cable is reconnected.
REMOVE V-RIBBED BELT
REMOVE GENERATOR ASSEMBLY
Remove the terminal cap.
Remove the nut and disconnect the wire harness from the terminal B.
Disconnect the generator connector and detach the wire harness clamp.
Remove the 2 bolts and generator assembly.
Remove the bolt and wire harness clamp bracket from the generator assembly.