PROCEDURE
INSPECT FRONT CENTER ULTRASONIC SENSOR
| *a | Component without harness connected (Front Center Ultrasonic Sensor) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the front center ultrasonic sensor.
INSPECT FRONT CORNER ULTRASONIC SENSOR
| *a | Component without harness connected (Front Corner Ultrasonic Sensor) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the front corner ultrasonic sensor.