DESCRIPTION
When the combination meter receives a hazard warning signal switch signal, the flasher IC turns on and hazard control is performed.
WIRING DIAGRAM
CAUTION / NOTICE / HINT
Note
When replacing the combination meter assembly, make sure to replace it with a new one.
PROCEDURE
READ VALUE USING GTS (HAZARD FLASHER SWITCH)
Using the GTS, read the Data List.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Hazard Flasher Switch | Hazard warning signal switch signal | ON or OFF | ON: Hazard switch on OFF: Hazard switch off |
- |
| Tester Display |
|---|
| Hazard Flasher Switch |
| Result | |||
|---|---|---|---|
|
| OK |
|
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE Click here |
| NG |
|
INSPECT AIR CONDITIONING CONTROL ASSEMBLY (HAZARD WARNING SWITCH)
Remove the air conditioning control assembly (hazard warning switch).
Inspect the air conditioning control assembly (hazard warning switch).
| Result | |||
|---|---|---|---|
|
| NG |
|
REPLACE AIR CONDITIONING CONTROL ASSEMBLY (HAZARD WARNING SIGNAL SWITCH) Click here |
| OK |
|
CHECK HARNESS AND CONNECTOR (AIR CONDITIONING CONTROL ASSEMBLY [HAZARD WARNING SWITCH] - COMBINATION METER ASSEMBLY AND BODY GROUND)
Disconnect the I13 air conditioning control assembly (hazard warning switch) connector.
Disconnect the I11 combination meter assembly connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| OK |
|
REPLACE COMBINATION METER ASSEMBLY Click here |
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |