OUTER MIRROR SWITCH INSPECTION

PROCEDURE


  1. INSPECT OUTER MIRROR SWITCH ASSEMBLY (for LHD, w/ Memory)


    1. A01HJUJC04
      *1 Mirror Retract Switch
      *2 Mirror Adjust Switch
      *3 Mirror Select Switch
      *a

      Component without harness connected

      (Outer Mirror Switch Assembly)

      Check the mirror retract switch.


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        8 (MR) - 10 (E2) Driving position Below 1 Ω

        11 (MF) - 10 (E2)

        8 (MR) - 10 (E2)

        AUTO position 10 kΩ or higher
        11 (MF) - 10 (E2) Retract position Below 1 Ω

        If the result is not as specified, replace the outer mirror switch assembly.

    2. Check the mirror select switch.


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        12 (E1) - 14 (MSW) R Below 10 Ω
        L 90 to 110 Ω
        Off 10 kΩ or higher
    3. Check the mirror adjust switch.


      1. Select the mirror select switch to the L position or R position.

      2. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        12 (E1) - 13 (M+) Mirror adjust switch pressed up 90 to 110 Ω
        Off 10 kΩ or higher
        Mirror adjust switch pressed down 437 to 503 Ω
        Off 10 kΩ or higher
        Mirror adjust switch pressed left 744 to 856 Ω
        Off 10 kΩ or higher
        Mirror adjust switch pressed right 225 to 275 Ω
        Off 10 kΩ or higher
    4. Check the switch illumination.


      1. Apply battery voltage between the terminals of the light and check the operation of the light.

        OK
        Measurement Condition Specified Condition

        Battery positive (+) → Terminal 6 (ILL+)

        Battery negative (-) → Terminal 15 (ILL-)

        Light comes on

        If the result is not as specified, replace the outer mirror switch assembly.

  2. INSPECT OUTER MIRROR SWITCH ASSEMBLY (for LHD, w/o Memory)


    1. A01HHRRC01
      *1 Mirror Retract Switch
      *2 Mirror Adjust Switch
      *3 Mirror Select Switch
      *a

      Component without harness connected

      (Outer Mirror Switch Assembly)

      Check the mirror retract switch.


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        12 (MR) - 9 (E) Driving position Below 1 Ω

        11 (MF) - 9 (E)

        12 (MR) - 9 (E)

        AUTO position 10 kΩ or higher
        11 (MF) - 9 (E) Retract position Below 1 Ω

        If the result is not as specified, replace the outer mirror switch assembly.

    2. Check the mirror select switch and mirror adjust switch.


      1. Select the mirror select switch to the L position.

      2. Measure the resistance according to the value(s) in the table below.

        Standard Resistance (for left side)
        Tester Connection Condition Specified Condition

        20 (VL) - 13 (B)

        19 (M+) - 15 (E)

        Up Below 1 Ω
        Off 10 kΩ or higher

        20 (VL) - 15 (E)

        19 (M+) - 13 (B)

        Down Below 1 Ω
        Off 10 kΩ or higher

        21 (HL) - 13 (B)

        19 (M+) - 15 (E)

        Left Below 1 Ω
        Off 10 kΩ or higher

        21 (HL) - 15 (E)

        19 (M+) - 13 (B)

        Right Below 1 Ω
        Off 10 kΩ or higher

        If the result is not as specified, replace the outer mirror switch assembly.

      3. Select the mirror select switch to the R position.

      4. Measure the resistance according to the value(s) in the table below.

        Standard Resistance (for right side)
        Tester Connection Condition Specified Condition

        18 (VR) - 13 (B)

        19 (M+) - 15 (E)

        Up Below 1 Ω
        Off 10 kΩ or higher

        18 (VR) - 15 (E)

        19 (M+) - 13 (B)

        Down Below 1 Ω
        Off 10 kΩ or higher

        23 (HR) - 13 (B)

        19 (M+) - 15 (E)

        Left Below 1 Ω
        Off 10 kΩ or higher

        23 (HR) - 15 (E)

        19 (M+) - 13 (B)

        Right Below 1 Ω
        Off 10 kΩ or higher

        If the result is not as specified, replace the outer mirror switch assembly.

    3. Check the switch illumination.


      1. Apply battery voltage between the terminals of the light and check the operation of the light.

        OK
        Measurement Condition Specified Condition

        Battery positive (+) → Terminal 10 (ILL+)

        Battery negative (-) → Terminal 22 (ILL-)

        Light comes on

        If the result is not as specified, replace the outer mirror switch assembly.

  3. INSPECT OUTER MIRROR SWITCH ASSEMBLY (for RHD, w/ Memory)


    1. A01HJJNC01
      *1 Mirror Retract Switch
      *2 Mirror Adjust Switch
      *3 Mirror Select Switch
      *a

      Component without harness connected

      (Outer Mirror Switch Assembly)

      Check the mirror retract switch.


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        11 (MF) - 10 (E2) Driving position Below 1 Ω

        11 (MF) - 10 (E2)

        8 (MR) - 10 (E2)

        AUTO position 10 kΩ or higher
        8 (MR) - 10 (E2) Retract position Below 1 Ω

        If the result is not as specified, replace the outer mirror switch assembly.

    2. Check the mirror select switch.


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        12 (E1) - 14 (MSW) R Below 10 Ω
        L 90 to 110 Ω
        Off 10 kΩ or higher
    3. Check the mirror adjust switch.


      1. Select the mirror select switch to the L position or R position.

      2. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        12 (E1) - 13 (M+) Mirror adjust switch pressed up 90 to 110 Ω
        Off 10 kΩ or higher
        Mirror adjust switch pressed down 437 to 503 Ω
        Off 10 kΩ or higher
        Mirror adjust switch pressed left 744 to 856 Ω
        Off 10 kΩ or higher
        Mirror adjust switch pressed right 225 to 275 Ω
        Off 10 kΩ or higher
    4. Check the switch illumination.


      1. Apply battery voltage between the terminals of the light and check the operation of the light.

        OK
        Measurement Condition Specified Condition

        Battery positive (+) → Terminal 6 (ILL+)

        Battery negative (-) → Terminal 15 (ILL-)

        Light comes on

        If the result is not as specified, replace the outer mirror switch assembly.

  4. INSPECT OUTER MIRROR SWITCH ASSEMBLY (for RHD, w/o Memory)


    1. A01HJZCC01
      *1 Mirror Retract Switch
      *2 Mirror Adjust Switch
      *3 Mirror Select Switch
      *a

      Component without harness connected

      (Outer Mirror Switch Assembly)

      Check the mirror retract switch.


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        11 (MF) - 9 (E) Driving position Below 1 Ω

        11 (MF) - 9 (E)

        12 (MR) - 9 (E)

        AUTO position 10 kΩ or higher
        12 (MR) - 9 (E) Retract position Below 1 Ω

        If the result is not as specified, replace the outer mirror switch assembly.

    2. Check the mirror select switch and mirror adjust switch.


      1. Select the mirror select switch to the L position.

      2. Measure the resistance according to the value(s) in the table below.

        Standard Resistance (for left side)
        Tester Connection Condition Specified Condition

        20 (VL) - 13 (B)

        19 (M+) - 15 (E)

        Up Below 1 Ω
        Off 10 kΩ or higher

        20 (VL) - 15 (E)

        19 (M+) - 13 (B)

        Down Below 1 Ω
        Off 10 kΩ or higher

        21 (HL) - 13 (B)

        19 (M+) - 15 (E)

        Left Below 1 Ω
        Off 10 kΩ or higher

        21 (HL) - 15 (E)

        19 (M+) - 13 (B)

        Right Below 1 Ω
        Off 10 kΩ or higher

        If the result is not as specified, replace the outer mirror switch assembly.

      3. Select the mirror select switch to the R position.

      4. Measure the resistance according to the value(s) in the table below.

        Standard Resistance (for right side)
        Tester Connection Condition Specified Condition

        18 (VR) - 13 (B)

        19 (M+) - 15 (E)

        Up Below 1 Ω
        Off 10 kΩ or higher

        18 (VR) - 15 (E)

        19 (M+) - 13 (B)

        Down Below 1 Ω
        Off 10 kΩ or higher

        23 (HR) - 13 (B)

        19 (M+) - 15 (E)

        Left Below 1 Ω
        Off 10 kΩ or higher

        23 (HR) - 15 (E)

        19 (M+) - 13 (B)

        Right Below 1 Ω
        Off 10 kΩ or higher

        If the result is not as specified, replace the outer mirror switch assembly.

    3. Check the switch illumination.


      1. Apply battery voltage between the terminals of the light and check the operation of the light.

        OK
        Measurement Condition Specified Condition

        Battery positive (+) → Terminal 10 (ILL+)

        Battery negative (-) → Terminal 22 (ILL-)

        Light comes on

        If the result is not as specified, replace the outer mirror switch assembly.