THERMOSTAT(for Cylinder Block) INSPECTION

PROCEDURE


  1. INSPECT THERMOSTAT (for Cylinder Block)

    A01HK0R

    Tech Tips

    The valve opening temperature is inscribed on the thermostat (for Cylinder Clock).


    1. Check that the valve is fully closed when the thermostat (for Cylinder Block) is at a low temperature (below 73 °C (163 °F)).

      If the valve is not fully closed, replace the thermostat (for Cylinder Block).

    2. Immerse the thermostat (for Cylinder Block) in water, and then gradually heat the water.

    3. Check that the valve of the thermostat (for Cylinder block) opens at the specified temperature.

      Standard valve opening temperature
      76 to 80 °C (169 to 176 °F)

      If the valve does not open as specified, replace the thermostat (for Cylinder Block).

    4. A01HE8LC01
      *a Valve Lift

      Check the valve lift.

      Standard valve lift
      8.0 mm (0.315 in.) or more at 91 °C (196 °F)

      If the valve lift is not as specified, replace the thermostat (for Cylinder Block).