ECM INSTALLATION

PROCEDURE


  1. INSTALL NO. 2 ECM BRACKET


    1. Install the No. 2 ECM bracket with the 2 screws.

      Torque:
      3.0 N*m  { 31 kgf*cm, 27 in.*lbf }
  2. INSTALL NO. 1 ECM BRACKET


    1. Install the No. 1 ECM bracket with the 2 screws.

      Torque:
      3.0 N*m  { 31 kgf*cm, 27 in.*lbf }
  3. INSTALL ECM


    1. Install the ECM with the 3 bolts.

      Torque:
      6.5 N*m  { 66 kgf*cm, 58 in.*lbf }
    2. B0059PY

      Connect the 2 ECM connectors and lower the 2 levers.

      Note


      • When connecting a connector, make sure that dirt, water and other foreign matter is not stuck between the connector and ECM.

      • Make sure that the 2 levers are securely lowered.

  4. INSTALL AIR CLEANER CASE SUB-ASSEMBLY


    1. Install the air cleaner case sub-assembly with the 3 bolts.

      Torque:
      7.0 N*m  { 71 kgf*cm, 62 in.*lbf }
    2. Attach the wire harness clamp to the air cleaner case sub-assembly.

  5. INSTALL AIR CLEANER FILTER ELEMENT SUB-ASSEMBLY


    1. Install the air cleaner filter element sub-assembly to the air cleaner case sub-assembly.

  6. INSTALL AIR CLEANER CAP AND HOSE

    Click here

  7. INSTALL NO. 2 CYLINDER HEAD COVER

    Click here

  8. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

    Note

    When disconnecting the cable, some systems need to be initialized after the cable is reconnected.

    Click here

  9. PERFORM INITIALIZATION

    Click here

  10. RESET MEMORY


    1. When replacing the ECM, perform the Reset Memory procedure (initialization).