AUTOMATIC TRANSAXLE SYSTEM, Diagnostic DTC:P271313

DTC Code DTC Name
P271313 Pressure Control Solenoid "D" Circuit Open

DESCRIPTION

Refer to the system description for DTC P27137F.

Click here

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Memory Note
P271313 Pressure Control Solenoid "D" Circuit Open Open or short is detected in shift solenoid valve SLT circuit for 1 second or more while driving (1-trip detection logic)
  • Open or short in shift solenoid valve SLT circuit

  • Wiring harness connector

  • Transmission wire

  • Shift solenoid valve SLT

  • ECM

Comes on DTC stored SAE: P2716

MONITOR DESCRIPTION

When an open or short in the shift solenoid valve SLT circuit is detected, the ECM interprets this as a fault. The ECM will illuminate the MIL and store this DTC.

WIRING DIAGRAM

B005848E04

CAUTION / NOTICE / HINT

Note

Perform registration and/or initialization when parts related to the automatic transaxle are replaced.

Click here

PROCEDURE


  1. CHECK HARNESS AND CONNECTOR (SHIFT SOLENOID VALVE SLT CIRCUIT)


    1. B0059HCC69
      *a

      Front view of wire harness connector

      (to ECM)

      Disconnect the ECM connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      C20-1 (SLT+) - C20-31 (SLT-) 20°C (68°F) 5.0 to 5.6 Ω
      C20-1 (SLT+) - Body ground and other terminals Always 10 kΩ or higher
      C20-31 (SLT-) - Body ground and other terminals Always 10 kΩ or higher
      Result
      Proceed to
      OK
      NG

    OK
    NG
  2. CHECK HARNESS AND CONNECTOR (WIRING HARNESS CONNECTOR - ECM)


    1. Disconnect the C21 wiring harness connector.

    2. Disconnect the C20 ECM connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      C21-15 (SLT+) - C20-1 (SLT+) Always Below 1 Ω
      C21-7 (SLT-) - C20-31 (SLT-) Always Below 1 Ω
      C21-15 (SLT+) or C20-1 (SLT+) - Body ground and other terminals Always 10 kΩ or higher
      C21-7 (SLT-) or C20-31 (SLT-) - Body ground and other terminals Always 10 kΩ or higher
      Result
      Proceed to
      OK
      NG

    NG
    OK
  3. INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLT)


    1. B0058FQC07
      *a

      Component without harness connected

      (Transmission Wire)

      Remove the wiring harness connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      A-12 (SLT+) - A-7 (SLT-) 20°C (68°F) 5.0 to 5.6 Ω
      A-12 (SLT+) - Body ground and other terminals Always 10 kΩ or higher
      A-7 (SLT-) - Body ground and other terminals Always 10 kΩ or higher
      Result
      Proceed to
      OK
      NG

    OK
    NG
  4. INSPECT SHIFT SOLENOID VALVE SLT


    1. B0058FPC14
      *1 Shift Solenoid Valve SLT

      Remove shift solenoid valve SLT.

      Click here

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 5.0 to 5.6 Ω
    3. Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

      OK
      Measurement Condition Specified Condition

      • Battery positive (+) with a 21 W bulb → Terminal 1

      • Battery negative (-) → Terminal 2

      Valve moves and makes an operating noise
      Result
      Proceed to
      OK
      NG

    OK
    NG