AUTOMATIC TRANSAXLE SYSTEM, Diagnostic DTC:P280713

DTC Code DTC Name
P280713 Pressure Control Solenoid "G" Circuit Open

DESCRIPTION

Changing from 1st to 6th is performed by the ECM turning shift solenoid valves SL1, SL2, SL3, SL4 and SL on and off. If an open or short circuit occurs in any of the shift solenoid valves, the ECM controls the remaining normal shift solenoid valves to allow the vehicle to be operated.

Click here

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Memory Note
P280713 Pressure Control Solenoid "G" Circuit Open An open or short circuit (output signal duty is 0% or 100%) is detected by the ECM in the shift solenoid valve SL4 circuit while driving and shifting gears (SL4 output signal duty is more than 0% and less than 100% under normal conditions) (1-trip detection logic).
  • Open or short in shift solenoid valve SL4 circuit

  • Wiring harness connector

  • Transmission wire

  • Shift solenoid valve SL4

  • ECM

Comes on DTC stored SAE: P2810

MONITOR DESCRIPTION

The ECM commands gear shifts by turning the shift solenoid valves on or off. When there is an open or short circuit in any shift solenoid valve circuit, the ECM detects the problem, illuminates the MIL and stores a DTC. The ECM also performs the fail-safe function and turns the other normal shift solenoid valves on or off (in case of an open or short circuit, the ECM stops sending current to the circuit).

Click here

WIRING DIAGRAM

B005848E06

CAUTION / NOTICE / HINT

Note

Perform registration and/or initialization when parts related to the automatic transaxle are replaced.

Click here

PROCEDURE


  1. CHECK HARNESS AND CONNECTOR (SHIFT SOLENOID VALVE SL4 CIRCUIT)


    1. B0059HCC71
      *a

      Front view of wire harness connector

      (to ECM)

      Disconnect the ECM connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      C20-13 (SL4+) - C20-12 (SL4-) 20°C (68°F) 5.0 to 5.6 Ω
      C20-13 (SL4+) - Body ground and other terminals Always 10 kΩ or higher
      C20-12 (SL4-) - Body ground and other terminals Always 10 kΩ or higher
      Result
      Proceed to
      OK
      NG

    OK
    NG
  2. CHECK HARNESS AND CONNECTOR (WIRING HARNESS CONNECTOR - ECM)


    1. Disconnect the C21 wiring harness connector.

    2. Disconnect the C20 ECM connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      C21-21 (SL4+) - C20-13 (SL4+) Always Below 1 Ω
      C21-20 (SL4-) - C20-12 (SL4-) Always Below 1 Ω
      C21-21 (SL4+) or C20-13 (SL4+) - Body ground and other terminals Always 10 kΩ or higher
      C21-20 (SL4-) or C20-12 (SL4-) - Body ground and other terminals Always 10 kΩ or higher
      Result
      Proceed to
      OK
      NG

    NG
    OK
  3. INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SL4)


    1. B0058FQC09
      *a

      Component without harness connected

      (Transmission Wire)

      Remove the wiring harness connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      A-22 (SL4+) - A-21 (SL4-) 20°C (68°F) 5.0 to 5.6 Ω
      A-22 (SL4+) - Body ground and other terminals Always 10 kΩ or higher
      A-21 (SL4-) - Body ground and other terminals Always 10 kΩ or higher
      Result
      Proceed to
      OK
      NG

    OK
    NG
  4. INSPECT SHIFT SOLENOID VALVE SL4


    1. B0058FPC14
      *1 Shift Solenoid Valve SL4

      Remove shift solenoid valve SL4.

      Click here

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 5.0 to 5.6 Ω
    3. Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

      OK
      Measurement Condition Specified Condition

      • Battery positive (+) with a 21 W bulb → Terminal 1

      • Battery negative (-) → Terminal 2

      Valve moves and makes an operating noise
      Result
      Proceed to
      OK
      NG

    OK
    NG