DESCRIPTION
When the stop and start system does not operate, check whether the operation is prohibited because the battery conditions are not met.
Tech Tips
| Hood Courtesy Switch | Battery Current | Battery Temperature (Start) | Battery Temperature |
| Idling Stop Rate | Total Idling Stop Rate | Integrated Current | Status of Battery Charge Control |
| Minimum Voltage (Cranking) | Minimum Voltage (After Cranking) | State of BBC | Stop&Start Operating Permission (Power Management) |
| Stop&Start Operating Permission (Start Minimum Voltage 2) | Stop&Start Operating Permission (Start Minimum Voltage 1) | Stop&Start Operating Permission (Integrated Current) | Stop&Start Operating Prohibition (Jump Start) |
| Battery Type | Ambient Temperature | - | - |
Note
If the Data List item Stop&Start Operating Permission (Power Management) is "NG" even after correcting a certain problem using the diagnostic troubleshooting procedures, the problem may be due to the battery charge amount being temporarily low or the battery may be deteriorated. However, there may be multiple overlapping conditions which are causing system operation to be prohibited, so make sure to always confirm all the diagnostic troubleshooting procedures.
PROCEDURE
CHECK MULTI-INFORMATION DISPLAY
Check whether the multi-information display displayed that the specified battery is not equipped.
Tech Tips
The multi-information display is displayed when the voltage decreases below the minimum voltage necessary for starting the non-specified battery when stop and start control is operated.
| Result | ||||||
|---|---|---|---|---|---|---|
|
| B |
|
GO TO STEP 14 Click here |
| A |
|
CHECK DTC OUTPUT
Connect the GTS to the DLC3.
Turn the engine switch on (IG).
Turn the GTS on.
Enter the following menus: Powertrain / Stop and Start / Trouble Codes.
Read the DTCs.
| Result | ||||||
|---|---|---|---|---|---|---|
|
| B |
|
GO TO DIAGNOSTIC TROUBLE CODE CHART Click here |
| A |
|
READ VALUE USING GTS (STOP&START OPERATING PERMISSION (POWER MANAGEMENT))
Tech Tips
Check whether stop and start control was prohibited based on the battery conditions or other conditions.
Connect the GTS to the DLC3.
Turn the engine switch on (IG).
Turn the GTS on.
Enter the following menus: Powertrain / Stop and Start / Data List / Stop&Start Operating Permission (Power Management).
| Tester Display |
|---|
| Stop&Start Operating Permission (Power Management) |
According to the display on the GTS, read the Data List.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Stop&Start Operating Permission (Power Management) | Permission of stop and start control based on the battery conditions | NG / OK | OK: Stop and start control is permitted due to battery condition, or Active Test (forced permission) is performed | - |
| Result | ||||||
|---|---|---|---|---|---|---|
|
| B |
|
END (CHECK OTHER STOP AND START CONTROL PERMISSION/PROHIBITION CONDITIONS) Click here |
| A |
|
READ VALUE USING GTS (BATTERY TYPE)
Connect the GTS to the DLC3.
Turn the engine switch on (IG).
Turn the GTS on.
Enter the following menus: Powertrain / Stop and Start / Data List / Battery Type.
| Tester Display |
|---|
| Battery Type |
Check the "Battery Type" Data List Item.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Battery Type | Set battery type | Specified / Other | Specified: Specified battery Other: Non-specified battery |
- |
Check whether the battery is specified or not specified.
| Result | ||||||
|---|---|---|---|---|---|---|
|
| B |
|
CHECK BATTERY SETTINGS AND EQUIPPED BATTERY Click here |
| A |
|
READ VALUE USING GTS (STOP&START OPERATING PROHIBITION (JUMP START))
Tech Tips
Check whether stop and start control was prohibited based on the jump start battery condition.
Connect the GTS to the DLC3.
Turn the engine switch on (IG).
Turn the GTS on.
Enter the following menus: Powertrain / Stop and Start / Data List / Stop&Start Operating Prohibition (Jump Start).
| Tester Display |
|---|
| Stop&Start Operating Prohibition (Jump Start) |
According to the display on the GTS, read the Data List.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Stop&Start Operating Prohibition (Jump Start) | Prohibition of stop and start control based on the jump start conditions | Permit / Prohibit | Prohibit: Engine started with the engine hood open and the engine switch turned on (START) | When Prohibit is displayed, stop and start control will be prohibited until the engine switch is turned off. |
| Result | ||||||
|---|---|---|---|---|---|---|
|
Tech Tips
A jump start is determined if the engine is started with the engine hood open.
After turning the engine switch off and waiting approximately 30 seconds, a jump start is determined to have not occurred if the engine is started with the engine hood closed.
| B |
|
READ VALUE USING GTS (HOOD COURTESY SWITCH) Click here |
| A |
|
READ VALUE USING GTS (STATE OF BBC)
Tech Tips
Check the operation of the backup boost converter.
Connect the GTS to the DLC3.
Turn the engine switch on (IG).
Turn the GTS on.
Enter the following menus: Powertrain / Stop and Start / Data List / State of BBC.
| Tester Display |
|---|
| State of BBC |
According to the display on the GTS, read the Data List.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| State of BBC | Backup boost converter status | Cycle Err / Overvoltage / Overload / Normal / Low Vol / Duty Err / Stop&Start Sensor Electric Supply Low / Stop&Start CPU Malfunction / BBC Overcurrent / Stop&Start Starter Overcurrent / Stop&Start Reduced Voltage Reset | Normal: Backup boost converter operating normally |
|
| Result | ||||||
|---|---|---|---|---|---|---|
|
| B |
|
GO TO BACKUP BOOST CONVERTER CIRCUIT Click here |
| A |
|
CHECK MULTI-INFORMATION DISPLAY (CHARGING SYSTEM)
Tech Tips
Check for any malfunctions in the generator power generation condition.
Check for any malfunctions in the charging system on the multi-information display.
| Result | ||||||
|---|---|---|---|---|---|---|
|
| B |
|
GO TO CHARGING SYSTEM for 8AR-FTS: Click here for 3ZR-FAE: Click here |
| A |
|
READ VALUE USING GTS (BATTERY TEMPERATURE, IDLING STOP RATE AND TOTAL IDLING STOP RATE)
Tech Tips
Check the idling stop rate.
Connect the GTS to the DLC3.
Turn the engine switch on (IG).
Turn the GTS on.
Enter the following menus: Powertrain / Stop and Start / Data List / Battery Temperature, Idling Stop Rate and Total Idling Stop Rate.
| Tester Display |
|---|
| Battery Temperature |
| Idling Stop Rate |
| Total Idling Stop Rate |
According to the display on the GTS, read the Data List.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Battery Temperature | Battery fluid temperature | Min.: -40°C (-40°F) Max.: 215°C (419°F) |
Changes according to actual temperature: Driving after engine warmed up | - |
| Idling Stop Rate | Rate of the idling stop time to the entire engine switch on (IG) time of this trip | Min.: 0% Max.: 255% |
- | - |
| Total Idling Stop Rate | Rate of the overall idling stop time to the overall power switch on (IG) time | Min.: 0% Max.: 255% |
- | - |
| Result | |||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||||||||
| B |
|
END (STOP AND START PROHIBITED DUE TO IDLING STOP RATE MORE THAN THRESHOLD OR TOTAL IDLING STOP RATE MORE THAN THRESHOLD) If Idling Stop Rate is more than threshold or Total Idling Stop Rate is more than threshold, leave the vehicle with the engine running until Idling Stop Rate drops below threshold or Total Idling Stop Rate drops below threshold. For details on the Idling Stop Rate and Total Idling Stop Rate thresholds, refer to System Description. Click here Prohibition according to the Idling Stop Rate is used to limit a high frequency of stop and start operations in order to ensure the lifespan of the battery. Operation may be prohibited again due to the customer usage conditions. |
| A |
|
READ VALUE USING GTS (BATTERY TEMPERATURE, AMBIENT TEMPERATURE)
Tech Tips
Check the battery fluid temperature.
Connect the GTS to the DLC3.
Turn the engine switch on (IG).
Turn the GTS on.
Enter the following menus: Powertrain / Stop and Start / Data List / Battery Temperature and Ambient Temperature.
| Tester Display |
|---|
| Battery Temperature |
| Ambient Temperature |
According to the display on the GTS, read the Data List.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Battery Temperature | Battery fluid temperature | Min.: -40°C (-40°F) Max.: 215°C (419°F) |
Changes according to actual temperature: Driving after engine warmed up | - |
| Ambient Temperature | Ambient temperature | Min.: -40°C (-40°F) Max.: 215°C (419°F) |
Close to ambient temperature | - |
| Result | ||||||
|---|---|---|---|---|---|---|
|
Tech Tips
The Battery Temperature hysteresis is 5°C (9°F) and the Ambient Temperature hysteresis is 1°C (1.8°F).
| B |
|
END (STOP AND START CONTROL PROHIBITED DUE TO ABNORMAL BATTERY TEMPERATURE) If Battery Temperature is not a suitable temperature, leave the vehicle at ambient temperature to allow Battery Temperature to return to a suitable temperature. Operation is prohibited due to the battery fluid temperature to ensure engine startability and protect the battery. This occurs due to the usage environment. |
| A |
|
READ VALUE USING GTS (STATUS OF BATTERY CHARGE CONTROL)
Tech Tips
Check whether stop and start control was prohibited based on the battery charge control mode.
Connect the GTS to the DLC3.
Start the engine and allow it to idle.
Turn the GTS on.
Enter the following menus: Powertrain / Stop and Start / Data List / Status of Battery Charge Control.
| Tester Display |
|---|
| Status of Battery Charge Control |
According to the display on the GTS, read the Data List.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Status of Battery Charge Control | Battery charge control status | Charge Control Coordination Mode / Stop and Start Standalone Mode / Refresh Charge Mode / Stop and Start Restriction Mode / Temperature High/Low Mode / Abnormal Mode / Battery Condition Judgment Mode / Low Temperature Mode | - | - |
| Result | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
| B |
|
Let the vehicle idle with the battery fluid temperature at 11°C (52°F) or higher for 30 to 60 minutes to complete the refresh charge. (The refresh charge is complete when Status of Battery Charge Control changes from "Refresh Charge Mode".) After the refresh charge completes, turn the engine switch off, wait for at least 30 seconds, and then start the engine again. If the vehicle enters refresh charge mode again while the engine is idling, the initial refresh charge did not properly complete, so wait for the refresh charge to complete. |
| C |
|
GO TO CHARGING SYSTEM for 8AR-FTS: Click here for 3ZR-FAE: Click here |
| D |
|
END (STOP AND START CONTROL PROHIBITED IN BATTERY CONDITION JUDGMENT MODE) |
| A |
|
READ VALUE USING GTS (STOP&START OPERATING PERMISSION (START MINIMUM VOLTAGE 1 AND 2)
Tech Tips
Check whether stop and start control was prohibited based on the minimum starting voltage of the battery condition.
Connect the GTS to the DLC3.
Turn the engine switch on (IG).
Turn the GTS on.
Enter the following menus: Powertrain / Stop and Start / Data List / Stop&Start Operating Permission (Start Minimum Voltage 1) and Stop&Start Operating Permission (Start Minimum Voltage 2).
| Tester Display |
|---|
| Stop&Start Operating Permission (Start Minimum Voltage 2) |
| Stop&Start Operating Permission (Start Minimum Voltage 1) |
According to the display on the GTS, read the Data List.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Stop&Start Operating Permission (Start Minimum Voltage 2) | Permission of stop and start control based on minimum voltage after cranking | NG / OK | OK: Minimum voltage when starter begins operation is equal to the threshold or higher | If Stop&Start Operating Permission (Start Minimum Voltage 1 and 2) are OK, stop and start control is permitted. |
| Stop&Start Operating Permission (Start Minimum Voltage 1) | Permission of stop and start control based on minimum voltage during starting | NG / OK | OK: Minimum voltage when cranking is equal to the threshold or higher | If Stop&Start Operating Permission (Start Minimum Voltage 1 and 2) are OK, stop and start control is permitted. |
| Result | ||||||
|---|---|---|---|---|---|---|
|
Tech Tips
The Data List item "Stop&Start Operating Permission (Start Minimum Volt 1 or 2)" is judged OK or NG according to the values of the following Data List items.
| Tester Display |
|---|
| Minimum Voltage (Cranking) |
| Minimum Voltage (After Cranking) |
| Battery Type |
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Minimum Voltage (Cranking) | Minimum voltage when cranking engine | Min.: -327.68 V Max.: 327.67 V |
6 to 11 V | Lowest battery voltage measured after the cranking. |
| Minimum Voltage (After Cranking) | Minimum voltage when starter begins operation | Min.: -327.68 V Max.: 327.67 V |
6 to 11 V | Minimum battery voltage while the starter starts operating. |
| Battery Type | Set battery type | Specified / Other | Specified: Specified battery Other: Non-specified battery |
- |
| Permission Criteria (Specified Battery) | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| Permission Criteria (Non-specified Battery) | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| B |
|
CHARGE OR REPLACE BATTERY AFTER CHECKING BATTERY STATE Click here |
| A |
|
READ VALUE USING GTS (STOP&START OPERATING PERMISSION (INTEGRATED CURRENT))
Tech Tips
Check whether stop and start control was prohibited based on the integrated current value battery condition.
Connect the GTS to the DLC3.
Turn the engine switch on (IG).
Turn the GTS on.
Enter the following menus: Powertrain / Stop and Start / Data List / Stop&Start Operating Permission (Integrated Current).
| Tester Display |
|---|
| Stop&Start Operating Permission (Integrated Current) |
According to the display on the GTS, read the Data List.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Stop&Start Operating Permission (Integrated Current) | Permission of stop and start control based on the integrated current value conditions | NG / OK | OK: Integrated current value is equal to the threshold or more | The status depends on the value of "Integrated Current". |
| Result | ||||||
|---|---|---|---|---|---|---|
|
| A |
|
END (TURN ELECTRICAL LOAD OFF AS MUCH AS POSSIBLE) |
| B |
|
READ VALUE USING GTS (INTEGRATED CURRENT)
Tech Tips
Judge the battery condition based on the integrated current value.
Connect the GTS to the DLC3.
Start the engine and allow it to idle.
Turn the GTS on.
Enter the following menus: Powertrain / Stop and Start / Data List / Integrated Current.
| Tester Display |
|---|
| Integrated Current |
According to the display on the GTS, read the Data List.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Integrated Current | Battery integrated current | Min.: -268434.456 Asec Max.: 268435.4558 Asec |
Differs according to vehicle condition (charge/discharge conditions) | - |
Tech Tips
Judge whether the Data List item "Integrated Current" is OK or NG according to the following table.
| Tester Display |
|---|
| Battery Current |
| Battery Temperature |
| Integrated Current |
| Status of Battery Charge Control |
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Battery Current | Battery current | Min.: -125 A Max.: 124.9961 A |
- | - |
| Battery Temperature | Battery fluid temperature | Min.: -40°C (-40°F) Max.: 215°C (419°F) |
Changes according to actual temperature: Driving after engine warmed up | - |
| Integrated Current | Battery integrated current | Min.: -268434.456 Asec Max.: 268435.4558 Asec |
Differs according to vehicle condition (charge/discharge conditions) | - |
| Status of Battery Charge Control | Battery charge control status | Charge Control Coordination Mode / Stop and Start Standalone Mode / Refresh Charge Mode / Stop and Start Restriction Mode / Temperature High/Low Mode / Abnormal Mode / Battery Condition Judgment Mode / Low Temperature Mode | - | - |
| Standard Integrated Current Value | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| Cause and Action to be Taken | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
Initialize* the battery integrated current using the GTS after charging the battery, and drive the vehicle until the stop and start control operates (approximately 5 to 40 minutes).
*: Use the GTS to perform Integrated Current Value Initialization.
Tech Tips
If the Data List item "Integrated Current" is 0 Asec or higher, it is not necessary to perform initialization.
When the battery state sensor assembly current value is normal, recharge or replace the battery
When the electrical load is large, a large amount of electrical discharge occurs. As a result, the integrated current value (battery charge amount) tends to drop causing operation to be prohibited.
| Result | ||
|---|---|---|
|
| NEXT |
|
CHARGE BATTERY AFTER CHECKING BATTERY STATE AND THEN INITIALIZE INTEGRATED CURRENT VALUE AND DRIVE VEHICLE UNTIL STOP AND START CONTROL OPERATES (APPROXIMATELY 5 TO 40 MINUTES) Refer to Integrated Current Value Initialization. CHARGE BATTERY AFTER CHECKING BATTERY STATE AND THEN INITIALIZE INTEGRATED CURRENT VALUE AND DRIVE VEHICLE UNTIL STOP AND START CONTROL OPERATES (APPROXIMATELY 5 TO 40 MINUTES) Click here |
CHECK BATTERY SETTINGS AND EQUIPPED BATTERY
Connect the GTS to the DLC3.
Turn the engine switch on (IG).
Turn the GTS on.
Enter the following menus: Powertrain / / Data List / Stop&Start Operating Prohibition (Jump Start). / Data List / Battery Type.
| Tester Display |
|---|
| Battery Type |
Check the "Battery Type" Data List Item.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Battery Type | Set battery type | Specified / Other | Specified: Specified battery Other: Non-specified battery |
- |
Check whether the battery is specified or not specified.
| Result | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| B |
|
When switching to a specified battery, Battery Type may not immediately switch to "Specified". To immediately switch it to "Specified", perform Switch Battery Type. Click here |
| A |
|
SWITCH BATTERY TYPE
Connect the GTS to the DLC3.
Turn the engine switch on (IG).
Turn the GTS on.
for 8AR-FTS:
Enter the following menus: Powertrain / Engine / Utility / Switch Battery Type.
| Tester Display |
|---|
| Switch Battery Type |
for 3ZR-FAE:
Enter the following menus: Powertrain / Engine and ECT / Utility / Switch Battery Type.
| Tester Display |
|---|
| Switch Battery Type |
Perform Switch Battery Type under Utility and set the Specified battery.
Enter the following menus: Powertrain / Stop and Start / Data List / Battery Type.
| Tester Display |
|---|
| Battery Type |
Check that the "Battery Type" Data List item is set to "Specified".
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Battery Type | Set battery type | Specified / Other | Specified: Specified battery Other: Non-specified battery |
- |
| Result | ||
|---|---|---|
|
| NEXT |
|
END |
READ VALUE USING GTS (HOOD COURTESY SWITCH)
Tech Tips
Check the engine hood courtesy switch (hood lock assembly).
Connect the GTS to the DLC3.
Turn the engine switch on (IG).
Turn the GTS on.
Enter the following menus: Powertrain / Stop and Start / Data List / Hood Courtesy Switch.
| Tester Display |
|---|
| Hood Courtesy Switch |
According to the display on the GTS, read the Data List.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Hood Courtesy Switch | Hood courtesy switch signal | ON / OFF | ON: Engine hood closed OFF: Engine hood opened |
- |
| Result | ||||||
|---|---|---|---|---|---|---|
|
Tech Tips
If the result is OK, the engine may have been started with the engine hood open to perform a jump start. Close the engine hood and start the engine again.
| B |
|
GO TO ENGINE HOOD COURTESY SWITCH CIRCUIT (OPERATION PROHIBITED AS ENGINE HOOD STATE DOES NOT CHANGE TO CLOSE) Click here |
| A |
|
READ VALUE USING GTS (STOP&START OPERATING PROHIBITION (JUMP START))
Check that the engine hood is closed.
Turn the engine switch off and wait for 30 seconds or more.
Turn the engine switch on (IG).
Turn the GTS on.
Enter the following menus: Powertrain / Stop and Start / Data List / Stop&Start Operating Prohibition (Jump Start).
| Tester Display |
|---|
| Stop&Start Operating Prohibition (Jump Start) |
Check that the Data List item "Stop&Start Operating Prohibition (Jump Start)" displays "Permit".
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Stop&Start Operating Prohibition (Jump Start) | Prohibition of stop and start control based on the jump start conditions | Permit / Prohibit | Prohibit: Engine started with the engine hood open and the engine switch turned on (START) | When Prohibit is displayed, stop and start control will be prohibited until the engine switch is turned off. |
| Result | ||
|---|---|---|
|
Tech Tips
Stop and start control may be prohibited if the engine was started with the engine hood open.
| NEXT |
|
END |
CHARGE OR REPLACE BATTERY AFTER CHECKING BATTERY STATE
Check the battery.
for 8AR-FTS:
for 3ZR-FAE:
Tech Tips
Charge or replace the battery according to the check result.
When the cable is disconnected from the battery terminal or the charging control system is checked (ECM connector is disconnected), do not perform this procedure, as there is a high possibility that the system may enter refresh charge mode and operation may be prohibited.
Check the starter inrush current reduction relay.
Connect the GTS to the DLC3.
Start the engine.
Turn the GTS on.
Enter the following menus: Powertrain / Stop and Start / Data List / Battery Current.
| Tester Display |
|---|
| Battery Current |
According to the display on the GTS, read the Data List.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Battery Current | Battery current | Min.: -125 A Max.: 124.9961 A |
- | - |
While idling, illuminate the headlights (Lo).
Tech Tips
The headlights (Lo) are illuminated so that charging control is prohibited, which sets the voltage to a fixed value.
Charge the battery for approximately 5 minutes after Battery Current drops 5 A or less.
Tech Tips
The Data List item Battery Current decreases when the battery is charged. If the battery is charged for 5 minutes after Battery Current drops to 5 A or less, it can be determined that the battery is sufficiently charged.
Turn off the headlights.
Turn the engine switch off and wait for 30 seconds or more.
Start the engine and check the following Data List items.
| Tester Display |
|---|
| Minimum Voltage (Cranking) |
| Minimum Voltage (After Cranking) |
| Stop&Start Operating Permission (Start Minimum Voltage 2) |
| Stop&Start Operating Permission (Start Minimum Voltage 1) |
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Minimum Voltage (Cranking) | Minimum voltage when cranking engine | Min.: -327.68 V Max.: 327.67 V |
6 to 11 V | Lowest battery voltage measured after the cranking. |
| Minimum Voltage (After Cranking) | Minimum voltage when starter begins operation | Min.: -327.68 V Max.: 327.67 V |
6 to 11 V | Minimum battery voltage while the starter starts operating. |
| Stop&Start Operating Permission (Start Minimum Voltage 2) | Permission of stop and start control based on minimum voltage after cranking | NG / OK | OK: Minimum voltage when starter begins operation is equal to the threshold or higher | If Stop&Start Operating Permission (Start Minimum Voltage 1 and 2) are OK, stop and start control is permitted. |
| Stop&Start Operating Permission (Start Minimum Voltage 1) | Permission of stop and start control based on minimum voltage during starting | NG / OK | OK: Minimum voltage when cranking is equal to the threshold or higher | If Stop&Start Operating Permission (Start Minimum Voltage 1 and 2) are OK, stop and start control is permitted. |
| Permission Criteria (Specified Battery) | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| Permission Criteria (Non-specified Battery) | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
Replace the battery in the following situations.
Stop&Start Operating Permission (Start Minimum Volt (1 and 2)) are not OK
Stop&Start Operating Permission (Start Minimum Volt (1 and 2)) are OK, but Min Voltage (Cranking) and Min Volt (After Cranking) values are close to permission criteria
| Result | ||
|---|---|---|
|
| NEXT |
|
INITIALIZE INTEGRATED CURRENT VALUE AND DRIVE VEHICLE UNTIL STOP AND START CONTROL OPERATES (APPROXIMATELY 5 TO 40 MINUTES) Refer to Integrated Current Value Initialization. INITIALIZE INTEGRATED CURRENT VALUE AND DRIVE VEHICLE UNTIL STOP AND START CONTROL OPERATES (APPROXIMATELY 5 TO 40 MINUTES) Click here |