8AR-FTS STARTING SERVICE DATA

STARTER ASSEMBLY (for 1.3 kW, 1.7 kW Type)
Tester Connection Condition Specified Condition
Battery positive terminal - Terminal 30 11.5 V 90 A or less
STARTER ASSEMBLY (w/ Stop And Start System)
Tester Connection Condition Specified Condition
Battery positive terminal - Terminal 30 11.5 V 130 A or less
MAGNET STARTER SWITCH ASSEMBLY (for 1.3 kW, 1.7 kW Type)
Tester Connection Condition Specified Condition
Terminal 50 - Terminal C Always Below 1 Ω
Terminal 50 - Switch body Always Below 2 Ω
REPAIR SERVICE STARTER KIT (w/ Stop And Start System)
Tester Connection Condition Specified Condition
Terminal SL1 - Magnet switch body Always Below 1 Ω
Terminal SL2 - Magnet switch body Always Below 2 Ω
STARTER COMMUTATOR END FRAME ASSEMBLY (for 1.3 kW, 1.7 kW Type)
Standard brush length 9.0 mm (0.354 in.)
Minimum brush length 4.0 mm (0.157 in.)
STARTER BRUSH HOLDER ASSEMBLY (w/ Stop And Start System)
Standard brush length 14.4 mm (0.567 in.)
Minimum brush length 9.0 mm (0.354 in.)
Standard spring load 22.3 to 27.3 N (2.3 to 2.8 kgf, 5.0 to 6.1 lbf)
Minimum spring load 13.8 N (1.4 kgf, 3.1 lbf)
STARTER COMMUTATOR END FRAME ASSEMBLY (for 1.3 kW, 1.7 kW Type)
Tester Connection Condition Specified Condition
Positive (+) brush - Negative (-) brush Always 10 kΩ or higher
STARTER ARMATURE ASSEMBLY
Tester Connection Condition Specified Condition
Segment - Segment Always Below 1 Ω
Segment - Coil core Always 10 kΩ or higher
STARTER ARMATURE ASSEMBLY (for 1.3 kW, 1.7 kW Type)
Standard commutator length 3.1 mm (0.122 in.)
Maximum commutator length 3.8 mm (0.150 in.)
STARTER ARMATURE ASSEMBLY (w/ Stop And Start System)
Maximum circle runout 0.05 mm (0.00197 in.)
Standard commutator diameter 29 mm (1.14 in.)
Minimum commutator diameter 28 mm (1.10 in.)
Standard undercut depth 0.4 mm (0.0157 in.)
Minimum undercut depth 0.2 mm (0.00787 in.)
ENGINE SWITCH
5 (SS1) - 6 (AGND) Not pushed 10 kΩ or higher
1 (SS2) - 6 (AGND)
5 (SS1) - 6 (AGND) Pushed Below 1 Ω
1 (SS2) - 6 (AGND)

Battery positive (+) → Terminal 9 (SWIL)

Battery negative (-) → Terminal 6 (AGND)

Illuminates
STARTER RELAY
Tester Connection Condition Specified Condition
3 - 5 Battery voltage not applied to terminals 1 and 2 10 kΩ or higher
Battery voltage applied to terminals 1 and 2 Below 1 Ω