Click here

ДАТЧИК ПОЛОЖЕНИЯ ПАРКИНГА / НЕЙТРАЛИ УСТАНОВКА

Click here
Click here Click here

PROCEDURE


  1. Click here

    INSTALL PARK/NEUTRAL POSITION SWITCH ASSEMBLY


    1. Move the shift lever to N.

    2. Temporarily install the park/neutral position switch assembly to the continuously variable transaxle assembly with the 2 bolts.

    3. Install the lock plate and lock nut to the park/neutral position switch assembly.

      6.9 N*m 70 kgf*cm 61 in.*lbf
    4. Temporarily install the control shaft lever to the park/neutral position switch assembly.

    5. A01UCJBC02
      *a P Position
      *b N Position

      Turn the control shaft lever clockwise until it stops, then turn it counterclockwise 2 notches.

    6. Remove the control shaft lever from the park/neutral position switch assembly.

    7. A01UFCWC03
      *a Neutral Basic Line
      *b Protrusion

      Align the protrusion with the neutral basic line.

    8. Hold the park/neutral position switch assembly in that position and tighten the 2 bolts.

      5.4 N*m 55 kgf*cm 48 in.*lbf
    9. A01UFB1

      Using a screwdriver, bend down the tabs of the lock plate.

    10. Install the control shaft lever to the park/neutral position switch assembly with the washer and nut.

      12.7 N*m 130 kgf*cm 9 ft.*lbf
    11. Connect the park/neutral position switch assembly connector.

  2. Click here

    CONNECT TRANSMISSION CONTROL CABLE ASSEMBLY


    1. Connect the transmission control cable assembly to the control shaft lever with the nut.

      12 N*m 122 kgf*cm 9 ft.*lbf
      Note:

      Before connecting the transmission control cable assembly, check that the park/neutral position switch assembly and shift lever are in neutral.

    2. Connect the transmission control cable assembly to the No. 1 transmission control cable bracket with a new clip.

  3. Click here

    INSPECT SHIFT LEVER POSITION

    Click here

  4. Click here

    ADJUST SHIFT LEVER POSITION

    Click here

  5. Click here

    INSPECT PARK/NEUTRAL POSITION SWITCH ASSEMBLY

    Click here

  6. Click here

    ADJUST PARK/NEUTRAL POSITION SWITCH ASSEMBLY

    Click here

  7. Click here

    INSTALL BATTERY CARRIER SUPPORT

    Click here

  8. Click here

    INSTALL BATTERY CARRIER

    Click here

  9. Click here

    INSTALL BATTERY

    Click here

  10. Click here

    INSTALL CENTER NO. 1 COWL TOP VENTILATOR LOUVER

    Click here

  11. Click here

    CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

    Note:

    When disconnecting the cable, some systems need to be initialized after the cable is reconnected.

    Click here