CAUTION / NOTICE / HINT
The necessary procedures (adjustment, calibration, initialization, or registration) that must be performed after parts are removed, installed, or replaced during the intake manifold removal/installation are shown below.
| Replacement Part or Procedure | Necessary Procedures | Effects/Inoperative when not Performed | Link |
|---|---|---|---|
| Battery terminal is disconnected/reconnected | Drive the vehicle until stop and start control is permitted (approximately 15 to 40 minutes) | Stop and start system | |
| Memorize steering angle neutral point | Panoramic view monitor system | ||
| Initialize back door lock | Power door lock control system | ||
| Initialize servo motor | Air conditioning system | ||
| Reset slide door close position | Power slide door system | ||
| Reset back door close position | Power back door system | ||
| Throttle body with motor assembly | Inspection After Repair |
|
|
| Cleaning the deposits from the throttle body with motor assembly |
PROCEDURE
REMOVE INTAKE MANIFOLD
REMOVE PCV VALVE (VENTILATION VALVE SUB-ASSEMBLY)
Slide the clip and disconnect the No. 2 ventilation hose from the PCV valve (ventilation valve sub-assembly).
Using a 19 mm deep socket wrench, remove the PCV valve (ventilation valve sub-assembly) from the ventilation case sub-assembly.